VII. Heat Pump Running Time

1.Determine the length of pump and heat pump operating time necessary for your particular requirements. Minimum run time should be the required hours to attain proper water filtration. Maximum run time obviously is 24 hours per day, or as required to reach desired water temperature, and depends on such things as weather, pool/spa size, covering, shading, etc.

2.If cooler or warmer water is desired, simply adjust the water temperature control and/or the pump and heat pump operating time accordingly, until the desired water temperature is reached.

NOTE: At the beginning of the heating season, or whenever the pool/spa water temperature is to be raised several degrees, the pool pump and heat pump may need to operate continuously for several days. During summer months, only a few hours per day may be necessary, or none at all.

VIII. Summer Shutdown

If you do not plan to use the heat pump during the summer months, secure and protect it as follows:

1.From the control panel, turn the control switch to Remote (OFF).

2.Turn the heat pump circuit breaker or disconnect switch to OFF.

3.Leave the valves set the way they are unless additional circulation is required. DO NOT stop all flow through the heat pump.

4.IMPORTANT: Remember to reset the valves before the next heating season, or the heat pump will not operate properly.

IX. Freeze Protection

If the heat pump is installed in a location subject to freezing conditions, it is important to protect the water circuit from freezing, just as should be done for the pump and filter.

System Drain-Down

1.Turn the heat pump circuit breaker or disconnect switch to OFF.

2.From the control panel, turn the control switch to Remote (OFF).

3.With the pool pump OFF, close the external shutoff valves and loosen the inlet and outlet water unions to allow water to drain.

4.Leave the drains open until the unit is started in the spring.

5.Cover the heat pump with a waterproof cover.

Continuous Pump Operation

It is also possible in some areas to prevent heat pump freeze damage by operating the pump continuously during freezing weather. However, this results in significantly higher pump operating cost. Further, if a sustained power failure occurs, the heat pump MUST be drained anyway, or freeze damage could result.