Raypak 500, 850, 300 Heat Exchanger Jacket Operating Controls Safeties, Gas Train Other, Boilers

Models: 500 300 850

1 8
Download 8 pages 12.19 Kb
Page 8
Image 8
HEAT EXCHANGER

HEAT EXCHANGER

JACKET

OPERATING CONTROLS

SAFETIES

GAS TRAIN

OTHER

 

 

 

 

 

 

 

Hot Water

 

Boilers

 

 

 

 

 

 

TM

Supply Boilers

 

 

 

 

 

 

 

 

(Type W)

 

(Type H)

 

 

 

 

 

 

 

 

 

 

ASME Section IV, National Board Registered, 160 PSI

• H Stamp





 

 

 

 

 

 

 

Heat Exchanger Tubes

 

• 316L Stainless Steel





 

 

 

 

 

 

 

Stainless Steel

 

• CSA Verified AB-1953 CA low lead compliant





 

 

 

 

 

 

 

 

Pressure Relief Valve

 

60 PSI





(loose)

 

125 PSI





 

 

 

 

 

• 30, 45, 75, 150 PSI





 

Temperature & Pressure Gauge (Loose)

 

 





Pump

 

• 120V, Single-Phase





 

 

 

 

 

 

 

Indoor/Outdoor Certified

 

 





Vent Terminal

 

• Outdoor





 

 

 

 

 

Through-the-Wall





 

Fully-Enclosed Controls

 

 





Combustible Floor Rated

 

 





 

 

 

 

 

 

 

 

120V Power Supply

 

 

 





On/Off Switch

 

 

 





Programmable Pump Time Delay, Single-Phase

• Included in Controller





Terminal Block Connections

• Enable / Disable





(Front mounted)

 

0-10 VDC Setpoint/Direct Drive Input





 

 

 

 

LCD diagnostic display with 10-Event History (2x20 character display, reads in plain English)





Temperature Controller with 3 Water Sensors

• (up to 5:1 Turndown)





 

 

 

 

 

• Outdoor Reset Sensor

N/A



 

 

 

 

 

 

Multiple Boiler Controller

• TempTracker Mod+ Hybrid, up to 16 boilers





 

 

 

 

 

 

 

 

 

 

 

Direct Spark Ignition System

1-try





 

 

 

 

 

4-try





 

High/Low Gas Pressure Switches

 

 





Blocked Vent and Air Pressure Switches

 

 





High Limit Switch

 

• Manual Reset, Fixed





 

 

 

 

 

• Automatic Reset, Fixed





 

 

 

 

 

 

Low Water Cut-Off, 24V

• With Manual Reset and Test Buttons





Flow Switch

 

 

 





 

 

 

 

 

 

 

Modulating Combination Gas Valve

 

 





Combustion Air Blower

 

 





Additional Safety Valve

• Motorized (externally mounted)





 

 

 

 

 

• Solenoid (externally mounted)





 

 

 

 

 

 

CSA-Certified Efficiency

• 94% at Full Fire





 

 

 

 

 

• 99% at Part Load





 

Air Filter

 

 

 





TruSeal Direct-Vent

 

 

 





Alarm Contacts

 

 

 





CSD-1 / GE GAP Control System

 

 





Low NOx

 

• Meets all current requirements





Condensate Drain and Trap

 

 





Condensate Neutralizer

 

 





  = Standard

  = Optional

 

 

 

 

 

Raypak, Inc. • 2151 Eastman Avenue, Oxnard, CA 93030 • phone: (805) 278-5300 • fax: (800) 872-8725 • www.raypak.com

© 2009 Raypak, Inc.

Cat. No. 1000.22 Effective: 01-01-10 Replaces: New

Page 8
Image 8