Hi Delta – Type H
Models 992BE-2342BE, 87% Efficiency
Model
NOTE: Pump location varies based on model and application.
RATES OF FLOW AND PRESSURE DROPS
Model | 20°F ∆T | 30°F ∆T | Min. Flow |
| Max. Flow |
| ||||||
GPM | ∆P (ft) | GPM | ∆P (ft) | GPM | ∆P (ft) |
| ∆T | GPM | ∆P (ft) |
| ∆T | |
992BE | 86 | 6.0 | 57 | 2.7 | 43 | 1.6 |
| 40 | 132 | 14.0 |
| 13 |
1262BE | 110 | 10.7 | 73 | 4.9 | 55 | 2.8 |
| 40 | 132 | 15.5 |
| 17 |
1532BE | 132 | 16.5 | 89 | 7.6 | 67 | 4.4 |
| 40 | 132 | 16.5 |
| 20 |
1802BE | N/A | N/A | 104 | 11.6 | 78 | 6.5 |
| 40 | 132 | 18.0 |
| 24 |
2002BE | N/A | N/A | 116 | 15.1 | 87 | 8.7 |
| 40 | 132 | 19.5 |
| 26 |
2072BE | N/A | N/A | 120 | 16.2 | 90 | 9.3 |
| 40 | 132 | 19.5 |
| 27 |
2342BE | N/A | N/A | N/A | N/A | 102 | 13.0 |
| 40 | 132 | 21.0 |
| 31 |
Basis is 30 GPM or 40°F ∆T for minimum flow, 132 GPM for maximum flow.
SPECIFICATIONS
|
|
|
|
|
|
|
|
|
| Approx. |
| MBTUH | Firing | A | H | K | T | W | Amp. | Shipping | |
Model | Input | Output | Stages | Width | NPT |
|
|
| Draw* | Wt. (Lbs.) |
992BE | 990 | 861 | 3 | 10 | 10 | <12 | 900 | |||
1262BE | 1260 | 1096 | 4 | 12 | 10 | <12 | 1010 | |||
1532BE | 1530 | 1331 | 4 | 12 | 10 | <12 | 1225 | |||
1802BE | 1800 | 1566 | 4 | 14 | 10 | <12 | 1350 | |||
2002BE | 1999 | 1739 | 4 | 14 | 10 | <12 | 1450 | |||
2072BE | 2070 | 1801 | 4 | 14 | 10 | <12 | 1450 | |||
2342BE | 2340 | 2036 | 4 | 16 | 10 | <12 | 1520 | |||
Dimensions are in inches. |
|
|
|
|
|
| * Without pump |
NOTES: 1. Rates shown are for natural or propane gas, and elevations up to 5,000 feet. For installation above 5,000 feet, please contact manufacturer. 2. Required natural gas pressure is 7 – 10.5” WC. Required propane gas pressure is 11 – 13” WC.
Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030 (805)
Catalog No.: 2000.451E | Effective: | Replaces: |