Technical Data

Digital Low NOx Gas Heaters

B

CAN BE

HEATER

 

ON A INSTALLED

DIRECTLY

 

COMBUSTIBLE

SURFACE!

 

C

INDOOR

DRAFTHOOD

31-13/16"

J

26-1/2"

ELECTRICAL

CONNECTION

20-1/2"

4-3/8"

8-7/8"

(6-5/8" ASME)

(3-3/8" ASME)

 

 

34"

 

STACKLESS

 

OUTDOOR TOP

7-3/4"

GAS

CONNECTION

A

(22-1/2" ASME)

28"

Amp Draw

120 volt 240 volt

6

3

 

 

 

 

 

 

 

 

Shipping Weights (lbs)

 

 

 

 

 

 

 

 

 

 

 

 

BTUH

(A)

(B)

(C)

(J)

 

 

w/ Polymer

w/ cast iron

 

 

 

 

Headers

Headers

 

Heater

Input

Cabinet

Flue

Indoor

Minimum

Gas

Water

 

and Stackless

and Stackless

Indoor

Model

(000)

Width

Diameter

Drafthood

 

Conn.

Conn.

Top

Top

Drafthood

R207A

199.5

20”

6”

55-5/8”

12”

3/4”

2”

174

193

12

 

 

 

 

 

 

 

 

 

 

 

R267A

266.0

23”

7”

56”

11-1/8”

3/4”

2”

197

216

15

 

 

 

 

 

 

 

 

 

 

 

R337A

332.5

26”

8”

57”

10-3/4”

3/4”

2”

219

238

17

 

 

 

 

 

 

 

 

 

 

 

R407A

399.0

29”

9”

58-1/2”

12-1/2”

3/4”

2”

237

256

20

 

 

 

 

 

 

 

 

 

 

 

Designation for a Digital heater using propane gas is “EP”; a Digital heater using natural gas is “EN”. Prefix “P” is for plastic (polymer) headers; “C” is for cast iron (ASME) headers.

Suffix “X” is for cupro-nickel tubing; “C” is for copper tubing

Example: P-R407A-EN-X= Plastic headers, 407 model size, digital, natural gas, cupro-nickel For elevations above 5000 feet consult the factory.