![ECONOPAKTM - COMMERCIAL HOT WATER SYSTEM](/images/new-backgrounds/35591/355913x1.webp)
ECONOPAKTM - COMMERCIAL HOT WATER SYSTEM
MODELS WH-90, WH-135, WH-195
331/4
16
41/2
THERMOSTAT CONN | 31/4 |
|
|
|
|
|
| ||
(ELECTRICAL CONN | GAS |
| ||
ON OTHER SIDE) |
| |||
| CONN |
| ||
| G |
|
|
221/8
261/2
3/4 NPT PIPE TO DRAIN
18
121/2
5
L
K
INLET
31/8 | 117/8 |
OUTLET |
|
| 6 |
| MIN |
19
A
Fig. 9287
All dimensions are in inches.
|
|
|
|
| TANK |
|
|
|
|
|
|
|
| 24 7/16 |
|
| HEATER |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
38 1/2 |
|
| 26 1/2 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LOWER |
| UPPER |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
80-GALLON TANK
Tank must be ordered seperately
1" NPT COUPLING | "RELIEF VALVE" LABEL |
8.00" DIAMETER |
| |
2" NPT |
| |
WATER |
| |
CONNECTION | MAGNESIUM ANODE | |
| ||
| (.840 O.D. X 53") | |
| (2 PLACES) | |
3/4" NPT COUPLING | "THERMOMETER" LABEL | |
| ||
NAMEPLATE/RATING | 24 7/16" | |
DIAMETER | ||
DECAL | ||
|
Drawing 1 | Drawing |
MODELS WH-260, WH-330, WH-400
ASME IDENTIFICATION | "SCALD DANGER" LABEL |
| |
PLATE WITH | INSULATION |
SERIAL NUMBER |
|
(ASME CODE TANKS ONLY) | STEEL TANK JACKET |
| "TANKSTAT" LABEL |
SERIAL NUMBER | 55 5/8" |
| 3/4" NPT COUPLING |
|
|
|
| K |
|
| PUMP |
|
|
|
| (OPTIONAL) |
|
|
|
| PUMP COVER |
|
|
|
| (OPTIONAL) |
|
|
|
| OUTDOOR |
|
|
| INLET | MODELS ONLY |
| J |
OUTLET |
|
| ||
|
|
|
| |
|
| (C) |
|
|
|
| INDOOR |
|
|
|
| DRAFT |
|
|
| 40" | 38 |
| |
| STACKLESS |
| ||
H | OUTDOOR |
|
|
|
WATER | TOP |
| ||
CONN. |
|
|
| |
G GAS |
| A | ||
| CONNECTION | |||
|
| |||
|
|
|
|
All dimensions are in inches.
|
|
|
|
| TANK |
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| 12 | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| A |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
38 1/2 |
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOWER |
| UPPER |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| HEATER |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
2" NPT |
| "FROM BOILER" |
|
WATER |
|
| |
CONNECTIONS |
| LABEL |
|
|
| 20 3/16" |
|
|
| 13 3/16" |
|
3 5/8" |
| 6 3/16" |
|
1 1/2" DIAMETER |
| "TO BOILER" LABEL |
|
(3 PLACES) |
| DRAIN VALVE 3/4" NPT | Fig. 9286 |
|
| ||
TANK SIZE | TYPE | SHIPPING |
|
(GALLONS) | WEIGHT (LBS) |
| |
|
| ||
80 | CODE | 255 |
|
80 | 198 |
|
Drawing 2 | Drawing |
|
|
|
|
| RECOVERY |
|
|
|
|
|
|
|
| SHIPPING | MINIMUM CLEARANCE FROM COMBUSTIBLE MATERIALS | ||||||
|
|
|
|
|
|
| GAS | WATER |
| FLUE |
| FOOT- |
|
|
|
|
|
| |||
REF | MODEL | INPUT | IN- | OUT- | ΔT=100° F | WIDTH | HEIGHT | CONN. | CONN. |
| DIA. |
| WEIGHT |
|
| RIGHT REAR | INDOOR | OUTDOOR |
| ||
|
| (LBS) |
|
|
| ||||||||||||||||
|
|
|
| LEFT SIDE |
| ||||||||||||||||
DWG | SIZE | (MBTUH) | DOOR | DOOR | (GPH)** | A | C | G | H | J | K | L | X | FLOOR | FRONT | TOP | TOP | VENT | |||
| RIGHT SIDE | ||||||||||||||||||||
| 90 | • |
| 90 | 11 | - | 1/2 | 1 | - | 5 | 5 3/4 | 47 | 105 | COMBUSTIBLE | SEE NOTE | 6 | 16 | N/A | 6 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
1 | 135 | • |
| 132 | 18 | - | 1/2 | 1 1/4 | - | 6 | 6 1/4 | 50 1/4 | 135 | COMBUSTIBLE | SEE NOTE | 6 | 16 | N/A | 6 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 195 | • |
| 192 | 18 | - | 1/2 | 1 1/4 | - | 7 | 6 1/4 | 50 1/4 | 140 | COMBUSTIBLE | SEE NOTE | 6 | 16 | N/A | 6 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 264 | • | • | 262 | 22 3/8 | 62 7/8 | 3/4 | 1 1/2 | 11 1/8 | 7 | - | 53 | 290 | COMBUSTIBLE* | SEE NOTE | 12 | 39 | UNOBSTRUCTED | 6 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
2 | 334 | • | • | 332 | 25 3/4 | 63 3/4 | 3/4 | 1 1/2 | 10 3/4 | 8 | - | 56 1/2 | 390 | COMBUSTIBLE* | SEE NOTE | 12 | 39 | UNOBSTRUCTED | 6 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 399 | • | • | 396 | 29 1/4 | 65 3/8 | 1 | 1 1/2 | 12 1/2 | 9 | - | 60 | 405 | COMBUSTIBLE* | SEE NOTE | 12 | 39 | UNOBSTRUCTED | 6 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Installation on combustible floor requires optional shield. ** Based on manufacturer’s rating. Models available for use with either Natural Gas or Propane. A front clearance of at least 24 inches is recommended for ade- quate service of burner tray and controls. Ratings shown are for elevations up to 2,000 feet. Ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
|
| MAXIMUM AND MINIMUM FLOW RATES | HEATER RATE OF FLOW AND PRESSURE DROP | RAYPAK,Inc. | ||||||||||
|
| 2151 Eastman Avenue • Oxnard, CA 93030 | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| MAX. FLOW/MIN. ΔT | MIN. FLOW/MAX. ΔT | 10°F (ΔT) | 20°F (ΔT) | 30°F (ΔT) | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MODEL | GPM |
| (°F )ΔT | ΔP(FT) | GPM | (°F )ΔT | ΔP(FT) | GPM | ΔP(FT) | GPM | ΔP(FT) | GPM | ΔP(FT) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
22 |
| 7 | 12.5 | 6 | 25 | 0.95 | 15 | 6.0 | 7.4 | 1.5 | N/A | N/A |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
33 |
| 7 | 10.0 | 9 | 25 | 0.75 | 22 | 4.6 | 11.1 | 1.2 | N/A | N/A |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
44 |
| 7 | 11.5 | 12 | 26 | 0.85 | 32 | 6.0 | 16 | 1.6 | N/A | N/A |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
45 |
| 10 | 9.4 | 20 | 22 | 1.90 | 45 | 9.4 | 22 | 2.2 | N/A | N/A |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
45 |
| 12 | 9.6 | 20 | 27 | 1.90 | N/A | N/A | 27 | 3.4 | N/A | N/A |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
45 |
| 15 | 9.8 | 20 | 33 | 2.10 | N/A | N/A | 33 | 5.2 | 22 | 2.3 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Raypak, Inc. reserves the right to make product changes or improvements at any time without notice.
Catalog No.: 3000.11H Effective: