R A Y N G E R M X P O R T A B L E N O N C O N T A C T T H E R M O M E T E R S

F E A T U R E S

 

MX2

MX4

MX4+

 

Adjustable emissivity

 

 

 

 

 

 

 

On-board emissivity table

-

 

 

 

 

 

 

 

*16-point laser circle spot; meets IEC

 

Class 2 & FDA Class II requirements

 

 

 

 

*Single Laser Class III

-

-

 

 

 

 

 

 

 

Audible/visible High alarm

 

 

 

 

 

 

 

Audible/visible Low alarm

 

 

 

 

 

 

 

 

MAX and MIN temperature

 

 

 

 

 

 

 

DIF and AVG temperature

-

 

 

 

 

 

 

 

Bar graph display

 

 

 

 

 

 

 

Data output: RS232 or

-

 

1 mV per degree (°C or °F)

 

 

 

 

100 points of data logging

-

 

 

 

 

 

 

 

Windows-compatible

-

-

 

 

 

 

 

 

 

Data Graphing Software

-

-

 

 

 

 

 

 

 

Power Supply (110 or 220V),

-

-

 

RS232 Computer Cable, 1.5 m (60 in),

 

 

 

 

K thermocouple probe

 

 

 

*MX2 available with either 16-point class II, or single point class III laser sighting system.

O P T I O N S / A C C E S S O R I E S

 

 

Windows-based Data Graphing Software*

Thermistor (NTC) probe

RS232 computer cable*

Portable thermal printer

Thermocouple K probe*

Calibration Certification

Plug-in Power Supply (110 or 220V)*

Soft pouch

*Standard with Raynger MX4+

 

 

 

S P E C I F I C A T I O N S

 

Temperature range

-30 to 900°C (-25 to 1600°F), MX2, MX4, MXCF

 

-50 to 500°C (-58 to 932°F), MXSZ

Accuracy*

±1% of reading or ±1°C (±2°F), whichever is greater

Repeatability*

±0.5% of reading or ±1°C (±2°F), whichever is greater

Response time

(95%) 250 mSec

Spectral response

8 to 14 µm, thermopile detector

Display resolution

tenth degree reading up to 900°C (0.2°F to 999.8°F)

Ambient operating range

0 to 50°C (32 to 120°F)

Relative humidity

10-95% RH noncondensing @ up to 30°C (86°F)

Storage temperature

-30 to 50°C (-25 to 122°F) without battery

Power

2 AA batteries, DC power for MX4 and MX4+

Tripod mount

1/4-20 UNC

Dimensions

200 x 170 x 50 mm (7.9 x 6.7 x 2 inches)

Weight

480 g (1 lb. 6 oz)

*only at 23°C (73°F)

 

Target Spot Sizes and Distances

25mm

19mm

286mm

@ 0m

@1.15m

@10m

1.0"

0.76"

11"

@ 0"

@ 3'10"

@ 32.8'

MX2, MX4, MX4+ and MXSZ

D:S = 60:1 at Focus Point

25mm

6mm

70mm

@ 0mm

@300mm

@1000mm

1.0"

0.24"

2.81"

@ 0"

@ 11.4"

@ 40"

MXCF (Close Focus)

D:S = 50:1 at Focus Point

A P P L I C A T I O N S

The rugged, ergonomic MX has many uses:

check for hot spots in electrical panels, circuit breakers, generators, and gearboxes

monitor supply and return registers, air stratification, and duct leakage

monitor temperatures of gasoline and diesel engine cylinders and railroad axles and bearings

food preparation and storage

Industrial predictive and preventative maintenance.

Checking for icing and deicing on planes and asphalt

Checking for depleted refrigeration media

Cold storage and walk-in refrigeration applications

Frozen food safety and processing

ISO 9000 proactive maintenance programs

Checking for bearing failures and motor misalignment

Power distribution trouble shooting

Electrical bench work in the shop or lab

For Sales and Ordering Contact:

5710 Kenosha Street Richmond, Illinois 60071 USA Phone: +1 (815) 678-2211 FAX: +1 (815) 678-3961 Internet: www.watlow.com e-mail: info@watlow.com

Your Authorized Watlow Distributor Is:

For Service and

Warranty Contact:

Worldwide Headquarters

Raytek Corporation

Santa Cruz, CA USA

Tel: 1 831 458 1110

800 866 5478 (U.S. and Canada only) Fax: 1 831 425 4561 www.raytek.com

Raytek, the Raytek logo, and Thermalert are registered trademarks of Raytek Corporation.

©2001 Raytek Corporation, Printed in USA, 3/01 Rev. A Specifications subject to change without notice. 3-1022

RIC-MX-0401

Page 2
Image 2
RayTek MX Series manual Specification S, P L I C a T I O N S