R A Y N G E R M X P O R T A B L E N O N C O N T A C T T H E R M O M E T E R S
F E A T U R E S |
| MX2 | MX4 | MX4+ | |
| Adjustable emissivity | ✓ | ✓ | ✓ | |
|
|
|
|
|
|
| - | ✓ | ✓ | ||
|
|
|
|
|
|
| ✓ | ✓ | ✓ | ||
| Class 2 & FDA Class II requirements |
|
|
| |
| *Single Laser Class III | ✓ | - | - | |
|
|
|
|
|
|
| Audible/visible High alarm | ✓ | ✓ | ✓ | |
|
|
|
|
|
|
| Audible/visible Low alarm |
| ✓ | ✓ | |
|
|
|
|
|
|
| MAX and MIN temperature | ✓ | ✓ | ✓ | |
|
|
|
|
|
|
| DIF and AVG temperature | - | ✓ | ✓ | |
|
|
|
|
|
|
| Bar graph display | ✓ | ✓ | ✓ | |
|
|
|
|
|
|
| Data output: RS232 or | - | ✓ | ✓ | |
| 1 mV per degree (°C or °F) |
|
|
| |
| 100 points of data logging | - | ✓ | ✓ | |
|
|
|
|
|
|
| - | - | ✓ | ||
|
|
|
|
|
|
| Data Graphing Software | - | - | ✓ | |
|
|
|
|
|
|
| Power Supply (110 or 220V), | - | - | ✓ | |
| RS232 Computer Cable, 1.5 m (60 in), |
|
|
| |
| K thermocouple probe |
|
|
|
*MX2 available with either
O P T I O N S / A C C E S S O R I E S |
|
| |
■ | ■ | Thermistor (NTC) probe | |
■ | RS232 computer cable* | ■ | Portable thermal printer |
■ | Thermocouple K probe* | ■ | Calibration Certification |
■ | ■ | Soft pouch |
*Standard with Raynger MX4+ |
|
|
|
S P E C I F I C A T I O N S |
|
Temperature range | |
| |
Accuracy* | ±1% of reading or ±1°C (±2°F), whichever is greater |
Repeatability* | ±0.5% of reading or ±1°C (±2°F), whichever is greater |
Response time | (95%) 250 mSec |
Spectral response | 8 to 14 µm, thermopile detector |
Display resolution | tenth degree reading up to 900°C (0.2°F to 999.8°F) |
Ambient operating range | 0 to 50°C (32 to 120°F) |
Relative humidity | |
Storage temperature | |
Power | 2 AA batteries, DC power for MX4 and MX4+ |
Tripod mount | |
Dimensions | 200 x 170 x 50 mm (7.9 x 6.7 x 2 inches) |
Weight | 480 g (1 lb. 6 oz) |
*only at 23°C (73°F) |
|
Target Spot Sizes and Distances
25mm | 19mm | 286mm |
@ 0m | @1.15m | @10m |
1.0" | 0.76" | 11" |
@ 0" | @ 3'10" | @ 32.8' |
MX2, MX4, MX4+ and MXSZ
D:S = 60:1 at Focus Point
25mm | 6mm | 70mm |
@ 0mm | @300mm | @1000mm |
1.0" | 0.24" | 2.81" |
@ 0" | @ 11.4" | @ 40" |
MXCF (Close Focus)
D:S = 50:1 at Focus Point
A P P L I C A T I O N S
The rugged, ergonomic MX has many uses:
■check for hot spots in electrical panels, circuit breakers, generators, and gearboxes
■monitor supply and return registers, air stratification, and duct leakage
■monitor temperatures of gasoline and diesel engine cylinders and railroad axles and bearings
■food preparation and storage
■Industrial predictive and preventative maintenance.
■Checking for icing and deicing on planes and asphalt
■Checking for depleted refrigeration media
■Cold storage and
■Frozen food safety and processing
■ISO 9000 proactive maintenance programs
■Checking for bearing failures and motor misalignment
■Power distribution trouble shooting
■Electrical bench work in the shop or lab
For Sales and Ordering Contact:
5710 Kenosha Street Richmond, Illinois 60071 USA Phone: +1 (815)
Your Authorized Watlow Distributor Is:
For Service and
Warranty Contact:
Worldwide Headquarters
Raytek Corporation
Santa Cruz, CA USA
Tel: 1 831 458 1110
800 866 5478 (U.S. and Canada only) Fax: 1 831 425 4561 www.raytek.com
Raytek, the Raytek logo, and Thermalert are registered trademarks of Raytek Corporation.
©2001 Raytek Corporation, Printed in USA, 3/01 Rev. A Specifications subject to change without notice.