NILES AUDIO CORPORATION – 1-800-BUY-HIFI – 1-305-238-4373 17
INSTALLATION (continued)
AddITIONAL MICROSENSORS
The Remote Control Anywhere! Kit includes one surface mount MicroSensor. The included
MSU250 main system unit will accommodate a second IR MicroSensor. Niles makes a variety of
MicroSensors for virtually any application. See your Niles dealer for more information.
RUNNING MICROSENSOR CABLE IN NEW CONSTRUCTION
SCHEdULING ANd PREPARATION
Plan to schedule the MicroSensor wiring after the electrical wiring is nished. That way you can
avoid cable routes which could potentially induce interference over the MicroSensor cable. The
basic rules are:
Never run the MicroSensor cable through the same hole as an electrical cable.
Never run the MicroSensor cable into the same J-box as electrical cable.
Avoid running the MicroSensor cable beside the electrical cable. Keep it at least 3 or 4 feet
away from any electrical power cable.
As side-by-side wiring is unavoidable in particular spots in every house, just move the MicroSensor
cable route away as soon as possible. If construction forces a side by side run for more than ten
feet, install metal conduit or shielded MicroSensor cable. Low-voltage cables such as doorbells,
intercoms, telephone, speaker, security, or television cannot cause interference on your MicroSensor
cables, so you can safely run all of them at the same time, through the same holes, side-by-side.