Maintenance

WARNING

Before cleaning, inspecting or repairing your unit, make sure that engine has stopped and is cool. Disconnect the spark plug terminal to avoid accidental engine starts.

Daily Inspection

Remove grass or dust, from the entire body.

Check that all nuts and screws are securely tightened, and no parts are missing.

Check for leakage of fuel.

Inspection every 25 hours

Remove the air cleaner element from the carburetor air intake cover and wash in warm, soapy water. Dry completely before installing.

Cleaner element

Cleaner cover

Check and clean the spark plug. Adjust the electrode gap to .024~.028in (0.6~0.7mm) if necessary.

.024 ~ .028 in (0.6~0.7mm)

Replacement plug: CHAMPION RCJ-6Y

Inspection every 100 hours

The muffler is equipped with a spark arrester to prevent red hot carbon from flying out of the exhaust outlet. In the State of California it is required by law (Section 4442 of the California Public Resources Code) to equip a spark arrester when a gas powered tool is used in any forest covered, brush covered, or grass covered unimproved land.

Speak

Arrester

Check and tighten each fastener.

Dismount the engine and check the clutch system to see if oil is observed between the clutch lining and its drum. If any, wipe it off with gasoline.

13

Page 13
Image 13
RedMax EDG2300 manual Maintenance, Inspection every 25 hours, Replacement plug Champion RCJ-6Y Inspection every 100 hours