SIZING GUIDE & SPECIFICATIONS

SIZING GUIDE & SPECIFICATIONS

SIZING GUIDE

CAPACITY

NOM SIZES

NOM WEIGHT

NOM WEIGHT

INDIRECT APPLICATION

DIRECT APPLICATION

(LITRES)

INDIRECT (FULL)

DIRECT (FULL)

HEAT-UP TIME/RE-HEAT TIME

HEAT-UP TIME/RE-HEAT TIME

150

1120 x 560

230kg

201kg

TWIN BATH

SINGLE BATH - 3 BED

30mins / 21mins

88mins / 50mins

 

 

 

 

200

1470 x 560

300kg

266kg

2 BATH & 2 SHOWERS

TWIN BATH

33mins / 24mins

108mins / 63mins

 

 

 

 

250

1770 x 560

360kg

319kg

3 BATH & 2 SHOWERS

TWIN BATH & SHOWER

36mins / 26mins

155mins / 100mins

 

 

 

 

Heat-up times through 50oC. Re-heat is 70% of volume.

COMPONENT SPECIFICATION

& REFERENCE NUMBERS

DESCRIPTION

SPECIFICATION

PART NUMBER

 

 

 

 

 

 

 

 

 

 

 

 

PRESSURE REDUCING VALVE

3.0 BAR CONTROL

97-392056

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NON RETURN VALVE

22MM X 22MM

97-392038

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESSURE GAUGE

0-10 BAR SCALE

97-392057

 

 

 

EXPANSION VALVE

6.0 BAR

97-392058

 

 

 

PRESSURE & TEMP RELIEF VALUE

7.0 BAR/95OC

97-392059

 

 

 

IMMERSION HEATER

13/4 - 240V ~ 3KW

97-392060

 

 

 

IMMERSION HIGH LIMIT THERMOSAT

80OC

97-392061

 

 

 

IMMERSION CONTROL THERMOSTAT

VARIABLE

97-392062

 

 

 

EXPANSION VESSEL UP TO 170 LITRE MODELS

3.0 BAR CHARGE, 12 LITRE CAPACITY

97-392063

 

 

 

EXPANSION VESSEL FOR 200 & 250 LITRE MODELS

3.0 BAR CHARGE, 18 LITRE CAPACITY

97-392064

 

 

 

TUNDISH

1/2“ X 22MM

97-392065

 

 

 

INSTALLATION GUIDE

24PP

97-392066

 

 

 

LABEL

-

97-392067

 

 

 

CYLINDER THERMOSTAT

CONTROL & HIGH LIMIT 80OC

97-392068

2 PORT VALVE

DANFOSS

97-392069