Regency U31-NG2 dimensions Gas Inserts, Minimum Fireplace Dimensions, U31 Regency Gas Insert

Models: U31-LP2 U31 U31-NG2

1 2
Download 2 pages 15.75 Kb
Page 1
Image 1
Gas Inserts

Gas Inserts

U31 Regency Gas Insert

U31 Regency Gas Insert

Model

 

U31-NG2

U31-LP2

Fuel Type

 

Natural Gas

Propane

 

 

 

 

Minimum Supply Pressure

5” W.C. (1.25 kPa)

12” W.C. (2.99 kPa)

 

 

 

 

Manifold Pressure - High

3.8” W.C. (0.95 kPa)

11” W.C. (2.74 kPa)

 

 

 

 

Manifold Pressure - Low

1.1” W.C. (0.27 kPa)

2.9” W.C. (0.72 kPa)

 

 

 

 

 

Orifice Size -Altitude 0-2000 ft.

 

 

#37 DMS

#52 DMS

 

 

 

 

 

Orifice Size - Altitude 2000-4500 ft.

 

 

#40 DMS

#53 DMS

 

 

 

 

 

Minimum Input

 

14,500 BTU/h

13,700 BTU/h

Altitude 0-2000 ft. (0-610m)

 

 

(4.25 kW)

(4.02 kW)

 

 

 

 

 

Minimum Input

 

13,000 BTU/h

12,400 BTU/h

Altitude 2000-4500 ft. (610-1372m)

 

 

(3.81 kW)

(3.63 kW)

 

 

 

 

 

Maximum Input

 

30,000 BTU/h

27,500 BTU/h

Altitude 0-2000 ft. (0-610m)

 

 

(8.79 kW)

(8.06 kW)

Maximum Input

 

27,200 BTU/h

25,000 BTU/h

Altitude 2000-4500 ft. (610-1372m)

 

 

(7.97 kW)

(7.33 kW)

 

 

 

 

 

Vent Sizing

 

 

4” B-Vent

4” B-Vent

 

 

 

 

 

 

 

Approved Venting Systems

 

Flex Vent Systems:

 

FPI AstroCap™ Flex Vent

 

 

 

 

 

Minimum Fireplace Dimensions

Gas Inserts

B

A

 

H

D

C

 

F

E

G

I

The minimum fireplace dimensions for the FPI gas fireplace insert are shown in the following diagrams:

 

 

1" (25mm)

 

 

Optional

 

2" (51mm)

 

 

 

Hearth Trim

 

4" (102mm)

Risers

 

6" (152mm)

 

 

 

 

 

 

Dimension

Description

U31 Regency

 

 

 

A

Faceplate Width

40-1/4” (1022mm)

B

Faceplate Height

26-1/4” (667mm)

C

Unit Width

27-7/8” (708mm)

D

Unit Height

20-1/4” (514mm)

E

Unit Depth

13-1/2” (343mm)

F

Faceplate to Vent Centerline

11-3/4” (298mm)

G

Faceplate Depth

1-3/8” (35mm)

H

Height to Vent Collar

20-7/8” (530mm)

I

Optional or Standard Front Depth

3-3/4” (95 mm)

 

 

 

NOTE: This unit may also be installed into new construction using a Zero Clearance Kit. Please refer to the Zero Clearance Kit Manual for details.

 

M

 

 

J

L

K

N

Dimension

Description

Contour

Molded

Faceplate

Faceplate

 

 

J

Height

21” (533mm)

21” (533mm)

K

Width

26-1/2” (673mm)

29” (737mm)

L

Depth

15” (381mm)

16” (406mm)

M

Max. Lintel Bar Depth

9” (229mm)

9” (229mm)

N

Rear Width

22-1/2” (572mm)

22-1/2” (572mm)

 

 

 

 

August 2008 Product Specifications Book