MAINTENANCE

REMOVING

VALVE ASSEMBLY

1) Shut off gas supply.

2) If optional fan is installed, disconnect power

source to stove.

3) Remove access panel.

a) Front panel on pedestal model. See diagram 1.

b) Panel from bottom of leg shield. See diagram 2.

Note: Access panel only has to be loos- ened to be taken out.

8)Ifoptionalfanisinstalled,removethermodisc tobracketbyremovingthree(3)phillipshead

M5 screws.

9) Remove front cover with Piezo Igniter by removing two (2) sheet metal screws.

10) Loosen four (4) phillips head M5 valve mounting screws from underside of fi rebox. Pushvalveassemblyforwardontheteardrop slots and drop down. Diagram 3.

16)Remove inlet pipe with pipe wrench. Note orientation of 90o elbow.

17)Remove two (2) phillips head M5 screws on each side of the valve.

18)Removevalveandremovegasout90o brass fi tting. Note orientation of fi tting.

INSTALLING

Diagram 1

Diagram 2

4)Disconnect gas line to stove.

5)Disconnect 3/8" NPT pipe from 90o elbow on valve.

6)Disconnect the two (2) switch wires from valve.

7)Remove two (2) orifice bracket screws inside fi rebox.

Diagram 3

11)Disconnect Piezo wire.

To remove valve from valve assembly, continue.

12)Remove two (2) thermopile wires.

13)Removethermocouple with a 9 mm(metric) wrench.

14)Remove pilot nut with an 11 mm wrench.

15)Remove valve to orifi ce nut with a 13/16" wrench.

VALVE ASSEMBLY

1)To install a new valve assembly, reverse instructions for removing valve. See as- sembly steps 1-11.

2)Check for leaks and manifold pressure. See Gas Pressure Test instructions.

3)To reinstall valve, reverse instructions for removing valve assembly, steps 12-18.

20

Regency® CLASSIC C33-3 Freestanding Gas Stove

Page 20
Image 20
Regency Wraps C33-LP3, C33-NG3 Removing Valve Assembly, Installing, To remove valve from valve assembly, continue