SAFETY INFORMATION

Continued

Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the heater.

Keep the appliance area clear and free from combus- tible materials, gasoline and other flammable vapors and liquids.

1.Install and use heater with care. Follow all local ordinances and codes. In the absence of local ordinances and codes, refer to the Standard for Storage and Handling of Liquefied Petro- leum Gas, ANSI/NFPA 58 and the Natural Gas Installation Code, CAN/CGA B149.2. This instructs on the safe storage and handling of propane/LP gases.

2.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

3.This heater may be used in a recreational enclosure or temporary construction work enclosure with a remote refillable propane/LP cyl- inder ONLY when the cylinder is located outdoors and the heater is used with the hose kit #LPA3090 (included with this heater). NEVER bring a refillable propane/LP cylinder indoors. A fire or explosion can occur causing property damage, serious injury or death.

4.Use only the hose and factory preset regulator provided with the heater. Use only replacement pressure regulators and hose assemblies specified in this manual. See Accessories, page 18.

5.Inspect the hose before each use of the heater. If it is evident there is excessive abrasion or wear, or the hose is cut, it must be re- placed prior to the heater being put into operation. Use replace- ment hose assembly kit #LPA3090 (see Accessories, page 18).

6.Use only propane gas set up for vapor withdrawal.

7.This heater shall not be installed in a bedroom or bathroom.

8.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. You must provide a minimum 10 square inches of ventilation air for adequate combustion.

9.If heater shuts off, do not relight until you provide fresh, out- side air. If heater keeps shutting off, have it serviced.

10.Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion.

11.Do not use heater if any part has been under water. Immedi- ately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

SAFETY INFORMATION

3

PRODUCT IDENTIFICATION

UNPACKING

 

 

 

12.Turn off and let cool before servicing. Only a qualified service person should service and repair heater.

13.Operating heater above elevations of 4,500 feet could cause pilot outage.

14.Turn off propane/LP supply when not in use.

15.Check heater for damage before each use. Do not use a dam- aged heater.

16.Do not alter heater. Keep heater in its original state.

17.Do not use heater if altered.

18.This heater can only be used in a recreational or commercial enclosure with a window or roof vent. This heater is not for outdoor use.

19.Before using the heater provide adequate ventilation. An area of 10 square inches of opening of a window or roof vent is needed for adequate combustion and ventilation air.

PRODUCT IDENTIFICATION

Ignitor

Control Knob

Button

Grill

Guard

Glass

FrontPanel

Panel

Heater

Cabinet

Regulator

Hose

Figure 1 - Vent-Free Propane/LP Gas Heater

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly return to dealer where you bought heater.

For morevisit www..com

110373-01B

Page 3
Image 3