6. The flash memory functions of the H8/3644 series are not supported by the emulator. Therefore,

do not apply 12 V to Vpp/P90 and TEST pins. If 12 V is applied, the emulator will detect it as

the test mode. The Vpp/P90 and TEST pins have circuits for protection against 12-v application,

as shown in figure 12.

To E6000 emulator station
To E6000 emulator station
10 k
27 k
15 k
470
Zener voltage: Approx. 6.0 V
x 2
Vpp/P90 pin (P90 is an I/O port)
From user system
From user system
TEST pin
Figure 12 Vpp/P90 and TEST Pin Protection Circuits 7. The P1 short connector is used for testing. Do not remove the inserted jumper pin.

Figure 13 P1 Short Connector

18