HD74HC1G66
Rev.8.00, Jan.27.2004, page 3 of 8
Absolute Maximum RatingsItem Symbol Ratings Unit Test Conditions
Supply voltage range VCC –0.5 to 7.0 V
Input voltage range *1VI–0.5 to VCC + 0.5 V
Output voltage range *1, 2 VO–0.5 to VCC + 0.5 V Output : H or L
Input clamp current IIK ±20 mA VI < 0 or VI > VCC
Output clamp current IOK ±20 mA VO < 0 or VO >VCC
Continuous output current IO±25 mA VO = 0 to VCC
Continuous current through
VCC or GND
ICC or IGND ±25 mA
Maximum power dissipation
at Ta = 25°C (in still air) *3
PT200 mW
Storage temperature Tstg –65 to 150 °C
Notes: T he absolute maximum ratings are values, which must not individually be exceeded, and
furthermore, no two of which may be realized at the same time.
1. The input and output voltage ratings may be exceeded if the input and output clamp-current
ratings are observed.
2. This value is limited to 5.5 V maximum.
3. The maximum package power dissipation was calculated using a junction temperature of 150°C.
Recommended Operating ConditionsItem Symbol Min Max Unit Test Conditions
Supply voltage range VCC 26V
Input voltage range VI/O 0V
CC V
Output voltage range VO0V
CC V
0 1000 VCC = 2.0 V
0 500 VCC = 4.5 V
Input rise / fall time
(Control input 10% to 90%)
tr, tf
0 400
ns
VCC = 6.0 V
Operating temperature Ta –40 85 °C
Note: Unused or floating control inputs must be held high or low.