M301N2T-PRB User’s Manual 5. Troubleshooting
REJ10J0037-0100 Rev.1.00 Mar.16, 2005 Page 40 of 48
5. Troubleshooting
This chapter describes how to troubleshoot when this product does not work properly.

5.1 Flowchart to Remedy the Troubles

Figure 5.1 shows the flowchart to remedy troubles from when power to the emulator is activated until the emulator debugger
starts up. Check this while the user system is not connected. For the latest FAQs visit the Renesas Tools Homepage.
http://www.renesas.com/en/tools
Turning on the power of PC4701
Not normal
PC4701 Front panel LEDs
1. Check emulator system connections.
See "2.4 Connecting the M30100T3-RPD-E" (page 22).
2. Redownload the firmware.
See "3.3 Downloading Firmware" (page 28).
3. Restart the PC4701 system.
Not normal or error displayed
Init dialog box of emulator debugger
displayed
1. Check the operating environment etc. of the emulator
debugger.
See the emulator debugger user's manual (online
manual).
2. Reinstall the emulator debugger.
Error displayed
See "5.2.2 Emulator Debugger Does Not Starts Up Properly
(Target Connected)" (page 42).
See "5.2.3 Emulator Debugger Does Not Starts Up Properly
(Target Not Connected)" (page 43).
Emulator debugger starts up properly
Figure 5.1 Flowchart to remedy troubles