M34571T2-CPE User’s Manual 2. Setup
REJ10J0972-0100 Rev.1.00 February 10, 2006 Page 30 of 72
2.7.2 If an Error is Detected in the Self-check
Table 2.4 lists how to remedy the troubles if the target status LED display is abnormal in the self-check. When an error is
detected, shut off the emulator and the user system and follow the steps in the Table 2.4.
Table 2.4 Error display in the self-check and how to remedy it
LED display
Blinking OFF
POWER CLOCK RESET RUN
Problem & Remedy
The emulator system is not working properly.
- Check that power is supplied to the emulator.
- The emulator may be damaged. Contact your local distributor.
A clock is not supplied to the emulator.
- Check that the oscillator circuit board (OSC-2) is attached.
- Check that the oscillator or oscillation module on an oscillator circuit board (OSC-2) is
operating normally.
The MCU is not controlled properly.
- Check that the MCU is mounted properly
- Check that the oscillation frequency of the oscillator circuit board (OSC-2) is within
the MCU specifications.
Others
The emulator system is not working properly.
- The emulator may be damaged. Contact your local distributor.
IMPORTANT
Notes on the Self-check:
Be sure to disconnect the user system before executing the self-check.
Use the preinstalled oscillator circuit board OSC-2 (6 MHz) to execute the self-check.
If the self-check does not result normally (excluding target status errors), the emulator may be damaged. Then,
contact your local distributor.