5. Connection Procedure
(1) For M38D29T2-RLFS-FP
1 Mount the NQPACK064SA160 to the foot pattern of the user system.
2 Attach the included M3T-F160-64NSA to the M38D29T2-RLFS.
3 Mount the YQPACK064SA on the NQPACK064SA160.
4 Attach the tip of the probe of the emulator to the M38D29T2-RLFS, and connect the M38D29T2-RLFS and YQPACK064SA.
(2) For M38D29T2-RLFS-HP
1 Mount the NQPACK064SD-ND to the foot pattern of the user system.
2 Attach the included M3T-F160-64NSD to the M38D29T2-RLFS.
3 Mount the YQPACK064SD on the NQPACK064SD-ND.
4 Attach the tip of the probe of the emulator to the M38D29T2-RLFS, and connect the M38D29T2-RLFS and YQPACK064SD.
Figure 3 Connection procedure of M38D29T2-RLFS-FP Figure 4 Connection procedure of M38D29T2-RLFS-HP
(1)
YQ- GUIDE (x4)
YQPACK064S A
NQPACK064SA 160
64-pin 0.8mm pitch
foot pattern
: No. 1 pin
(4)
PLQP0064GA - A (64P6U-A)
Emulator
(2)
(3)
M3T-F160-64NSA
(4)
Be sure to align the pins.
M38D29T2 - RLFS
(1)
YQ-GUIDE (x4)
YQPACK064SD
NQPACK064SD - ND
64-pin 0.5mm pitch
foot pattern
: No. 1 pin
(4)
PLQP0064 KB -A ( 64P 6Q-A )
Emulator
(2)
(3)
M3T-F 160-64NSD
(4)
Be sure to align the pins.
M38D29T2 - RLFS
6. External Dimensions
Figure 5 External dimensions
64.0
45. 0
5.4
9.2

CN2

VCC
GNDRESET +
R1
C6
C5
R5R6
(3/4)