(3/4)
(See Figure 3)
The procedure for connecting the M3T-F160-100NSD is shown 
below. 
(1) Mount the NQPACK100SD-ND on the user system. 
(2) Attach the YQPACK100SD on the NQPACK100SD-ND. 
(3) Secure the four corners of the YQPACK100SD with the 
YQ-GUIDE's. 
● Do not use the screws included with the 
YQPACK100SD for fixing the YQPACK100SD. 
● Do NOT used the screwdriver included with the 
NQPACK100SD-ND that is used only for the 
HQPACK100SD. 
(4) Attach the probe of the emulation pod to the M3T-
F160-100NSD. 
(5) Connect M3T-F160-100NSD on the YQPACK100SD. 
M3T-F160-100NSD
YQPACK100SD
NQPACK100SD-ND
100-pin 0.5-mm-pitch
(100P6Q-A) foot pattern
(1)
(2)
(3)
(5)
(4)
Use a slotted screwdriver.
YQ-GUIDE (x4)
: No. 1 pin
  Be sure to align the pins.
FLX160-PRB
or
M3xxxxTx-EPB
Figure 3 Connection procedure of the M3T-F160-100NSD 