4.4 Precautions When Opening and Closing IC SocketWhen opening and closing the IC socket, hold the adapter horizontally as shown in Figure 4.4.
Otherwise the inside of the IC socket may become damaged and cause an electrical insulation failure.
Figure 4.4 Holding the adapter in a horizontal position
4.5 Precautions When Handling AdapterDo not directly touch the connector in the IC socket and the pins on the PROM programmer connector
because dirt may cause an electrical insulation failure.
When not using this product, attach the connector pins of this product to the conductive sponge as
it was shipped from the factory.
4.6 Setting Programming AreaWhen writing and erasing programs, be sure to set the programming area. And also, specify its device
of the PROM programmer.
Table 4.1 Programming area
MCU type name Internal flash
memory
area of MCU
M5M28F101
ROM size Programming areaDevice
PROM programmer
M38039FFSP
M38039FFFP
M38039FFHP
M38049FFSP
M38049FFFP
M38049FFHP
M38869FFAGP
M38869FFAHP
100016--FFFF16
0100016--0FFFF16
60 KB