Section 4 Verifying Operation
1. When using the E6000 emulator for the H8S/2633 series, turn on the emulator according to the
procedures described in the E6000 Series Emulator User's Manual (HS2000EPI61HE).
2. Verify the user system interface cable connections by accessing the external memory and ports
to check the bus states of the pins with the MEMORY_FILL c ommand (emulator command) . If
an error is detected, recheck the soldered IC socket and the location of pin 1.
3. The emulator connected to this user system interface cable supports two kinds of clock sources
as the MCU clock: an emulator internal clock and an external clock on the user system. For
details, refer to the Emulator Supplementary Information (HS2633EPI61HE).
To use the emulator internal clock
Select the clock in the emulator station as the system clock (φ), by using the CLOCK
command (emulator comman d).
To use the external clock on the user system
Supply the external clock from the user system to the emulator. Connect a crystal oscillator
to the EXTAL and XTAL terminals for the system clock (φ), and to the OSC1 and OSC2
terminals for the subclock. The user system interface cable has the oscillator circuits shown
in figure 10. For details, refer to section 19, Clock Pulse Generator, in the H8S/2237 Series
Hardware Manual.
15
R2 270
R1 1 MHCU04
HCU04
To E6000
emulator
EXTAL XTAL
System clock oscillator
R6 470 k
R5 3.3 M
HCU04 HCU04 HCU04
To E6000
emulator
OSC1 OSC2
Subclock oscillator
R12 2.2 k
R13 10 k
Figure 10 Clock Oscillator Circuits