RECOVERY CAPACITIES

AdvantagePlus Gas continued.

RECOVERY CAPACITIES

Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises

 

MODEL

INPUT (BTU/HR)

THERMAL

 

40°F

50°F

60°F

70°F

80°F

90°F

100°F

110°F

120°F

130°F

140°F

 

 

NUMBER

NAT. & LP

EFFICIENCY

UNITS

(22°C)

(28°C)

(33°C)

(39°C)

(45°C)

(50°C)

(56°C)

(61°C)

(67°C)

(72°C)

(78°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE45-100

100,000

95%

GPH

288

230

192

165

144

128

115

105

96

N/A

N/A

 

 

LPH

1090

872

726

623

545

484

436

396

363

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE45-130

130,000

95%

GPH

374

299

249

214

187

166

150

136

125

N/A

N/A

 

HE80-130

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE119-130

 

 

LPH

1417

1133

944

809

708

630

567

515

472

N/A

N/A

 

 

HE80-160

160,000

95%

GPH

461

368

307

263

230

205

184

167

154

N/A

N/A

 

 

HE119-160

LPH

1744

1395

1162

996

872

775

697

634

581

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE80-199

199,000

95%

GPH

573

458

382

327

286

255

229

208

191

N/A

N/A

 

 

LPH

2169

1735

1446

1239

1084

964

867

789

723

N/A

N/A

 

HE119-199

 

 

 

BOOSTER

MODELS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE45-160

160,000

95%

GPH

461

368

307

263

230

205

184

167

154

142

132

 

 

LPH

1744

1395

1162

996

872

775

697

634

581

536

498

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE45-199

199,000

95%

GPH

573

458

382

327

286

255

229

208

191

176

164

 

 

LPH

2169

1735

1446

1239

1084

964

867

789

723

667

620

 

 

 

 

 

 

Recovery rating is based on thermal efficiencies obtained in an UL certified laboratory.

MAXIMUM DELIVERY

In U.S. Gallons and Liters (Includes useable storage and recovery for indicated times)

 

MODEL

 

 

INPUT (BTU/HR)

TEMP.

 

5

10

15

20

30

45

1

2

3

MIN. TO RECOVER

 

 

NUMBER

GALLONS

LITERS

NAT. & LP

RISE

UNITS

MIN.

MIN.

MIN.

MIN.

MIN.

MIN.

HR.

HR.

HR.

CONTENTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE45-100

45

170

100,000

100°F

GAL.

41

51

60

70

89

118

147

262

377

23

 

 

37.7°C

LTR.

156

192

228

265

337

446

555

991

1427

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE45-130

45

170

130,000

100°F

GAL.

44

56

69

81

106

144

181

331

481

18

 

 

37.7°C

LTR.

166

214

261

308

403

544

686

1253

1819

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE80-130

80

303

130,000

100°F

GAL.

68

81

93

106

131

168

206

355

505

32

 

 

37.7°C

LTR.

259

306

354

401

495

637

779

1345

1912

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE119-130

119

450

130,000

100°F

GAL.

96

108

121

133

158

196

233

383

532

48

 

 

37.7°C

LTR.

363

410

457

504

599

750

882

1449

2015

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE45-160

45

170

160,000

100°F

GAL.

47

62

78

93

124

170

216

400

584

15

 

 

37.7°C

LTR.

177

235

294

352

468

642

817

1514

2211

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE80-160

80

303

160,000

100°F

GAL.

71

87

102

117

148

194

240

424

609

26

 

 

37.7°C

LTR.

270

328

386

444

561

735

909

1607

2304

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE119-160

119

450

160,000

100°F

GAL.

99

114

129

145

175

221

268

452

636

39

 

 

37.7°C

LTR.

373

432

490

548

664

838

1013

1710

2408

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE45-199

45

170

199,000

100°F

GAL.

51

70

89

108

146

203

261

490

719

12

 

 

37.7°C

LTR.

192

264

336

408

553

770

987

1854

2721

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE80-199

80

303

199,000

100°F

GAL.

75

94

113

132

171

228

285

514

743

21

 

 

37.7°C

LTR.

284

357

429

501

646

863

1079

1947

2814

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE119-199

119

450

199,000

100°F

GAL.

102

121

141

160

198

255

312

542

771

31

 

 

37.7°C

LTR.

338

460

532

604

749

966

1183

2050

2918

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All models have a maximum setpoint of 160°F with the exception of the HE45-160 and HE45-199 booster models. The HE45-160 and HE45-199 have a maximum setpoint of 180°F.

DIMENSIONAL INFORMATION

All dimensions shown in English and Metric

 

MODEL

 

A

B

C

D

E

F

G

H

 

WATER CONNECTIONS

APPROX

 

NUMBER

UNITS

VENT

 

 

SHIPPING WT.

 

INLET

OUTLET

 

HE45-100

inches

42

23 1/2

32

35

5

25 1/4

27 9/16

5 7/8

2

1

1

175 lbs.

 

HE45-130

mm

1067

597

813

889

127

641

700

149

51

25

25

79 kgs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE45-160

inches

42

23 1/2

32

35

5

25 1/4

27 9/16

5 7/8

3

1

1

175 lbs.

 

HE45-199

mm

1067

597

813

889

127

641

700

149

76

25

25

79 kgs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE80-130

inches

72

23 1/2

32

65

5

25 1/4

20 1/4

7 3/4

3*

1-1/2

1-1/2

235 lbs.

 

HE80-160

 

mm

1854

597

813

1651

127

641

514

197

76

38

38

106 kgs

 

HE80-199

 

HE119-130

inches

73

27

36

66 3/4

6 3/4

28 7/8

22

9 1/2

3*

1-1/2

1-1/2

405 lbs.

 

HE119-160

 

mm

1854

686

914

1695

171

733

559

241

76

38

38

184 kgs

 

HE119-199

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0" CLEARANCE TO COMBUSTIBLES ON ALL ADVANTAGE PLUS UNITS, HOWEVER, A 24"

CONTROL PANEL SERVICE CLEARANCE IS RECOMMENDED.

MODELS WITH INPUTS OF

100,000 BTU AND

130,000 BTU ARE CERTIFIED TO VENT WITH 2" SCHEDULE 40 PVC, CPVC OR ABS PIPE

*130,000 BTU models are certified to be installed with 2" venting. All models require a 120V power source.

See use and care manual for venting details.

Page 2
Image 2
Rheem 130, 100 manual Recovery Capacities, Maximum Delivery, Dimensional Information