Rheem 80F, 60F, 70F, 90F Recovery Capacities, Electrical Characteristics, Dimensional Information

Models: 90F 70F 120F 80F 50F 60F 110F 40F 5 100F

1 4
Download 4 pages 19.6 Kb
Page 3
Image 3
Eclipse Construction Features

Eclipse Construction Features

Composite tank and high density polyethylene dent and scratch resistant jacket.

No anode rod required.

Models are in two sizes with capacity of 85 or 105 gallons in 42 total variations.

Input options are: 12.4, 18, or 24 kW.

Voltage options are 208, 240 or 480 VAC in either single phase or 3-phase and 277 VAC in single phase only.

Element wattages are 3100, 4500 or 6000 in each of the four voltages. The elements are low watt density design (46, 67, 90 watts/sq. in.) with stainless (Inconel) sheath.

The four Inconel elements are spaced on the front along a vertical line for easy access.

The power control circuits use 2 surface mounted thermostats and operate in two stages so that a lower control thermostat is for the lower two elements and an upper control is for the upper two elements. The lower element will provide recovery for all needs and the upper two will kick in additionally for larger demands.

170º F maximum delivered temperature.

System Sentinel LED indicators are provided for each element to show power on.

A switch is provided in the control circuit for installation dry fire protection. See label.

A temperature and pressure relief valve is installed on top of the unit.

3/4” full port, full flow brass drain valve.

Standards approved to UL 1453 and UL/NSF 005.

Eclipse Specifications

RECOVERY CAPACITIES

Recovery at various temperature rises

 

 

 

 

 

 

 

TEMPERATURE RISE

 

 

 

 

 

EQUIVALENT

 

 

 

 

 

 

 

 

 

 

MODEL NUMBER

INPUT KW

BTU/HR

UNITS

40°F

50°F

60°F

70°F

80°F

90°F

100°F

110°F

120°F

ME85-12

12.4

42,309

GPH

126

100

84

72

63

55

50

45

42

ME85-18

18

61,420

GPH

186

149

124

106

93

83

74

68

62

ME85-24

24

81,893

GPH

248

199

165

142

124

110

99

90

83

ME105-12

12.4

42,309

GPH

126

100

84

72

63

55

50

45

42

ME105-18

18

61,420

GPH

186

149

124

106

93

83

74

68

62

ME105-24

24

81,893

GPH

248

199

165

142

124

110

99

90

83

ELECTRICAL CHARACTERISTICS

 

 

 

 

 

 

 

FULL LOAD CURRENT – IN AMPERES

 

 

 

NUMBER

ELEMENT

NUMBER

NUMBER

208V

240V

277V

480V

MODEL NUMBER

INPUT KW

OF ELEMENTS

WATTAGE

OF FUSES

OF THERMOSTATS

PHASE 1

PHASE 3

PHASE 1

PHASE 3

PHASE 1

PHASE 1

PHASE 3

ME85-12

12.4

4

3100

8

2

60

39

52

34

45

26

17

ME85-18

18

4

4500

8

2

87

57

75

50

65

38

25

ME85-24

24

4

6000

8

2

115

76

100

66

87

50

35

ME105-12

12.4

4

3100

8

2

60

39

52

34

45

26

17

ME105-18

18

4

4500

8

2

87

57

75

50

65

38

25

ME105-24

24

4

6000

8

2

115

76

100

66

87

50

35

DIMENSIONAL INFORMATION

All dimensions shown in inches

 

 

CAPACITY

MAX. DELIVERED

WATER HEATER

WATER HEATER

HEIGHT TO

APPROX. SHIPPING

MODEL NUMBER

INPUT KW

GALLONS

TEMPERATURE

HEIGHT

DIAMETER

WATERCONNECTION

WEIGHT (LBS.)

ME85-12

12.4

85

170º

66-1/4

28-1/4

70-1/4

170

ME85-18

18

85

170º

66-1/4

28-1/4

70-1/4

170

ME85-24

24

85

170º

66-1/4

28-1/4

70-1/4

170

ME105-12

12.4

105

170º

66-1/2

30-1/4

70-3/4

185

ME105-18

18

105

170º

66-1/2

30-1/4

70-3/4

185

ME105-24

24

105

170º

66-1/2

30-1/4

70-3/4

185

Commercial water heaters

from Rheem-Ruud

Page 3
Image 3
Rheem 80F, 60F, 70F, 90F Recovery Capacities, Electrical Characteristics, Dimensional Information, Commercial water heaters