V VENT TERMINAL

X AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

Horizontal Vent Terminal Location

The following information should be used for determining the proper location of the vent terminal for direct vent tankless water heaters.

 

 

Canadian Installations 1

US Installations 2

A=

Clearance above grade, veranda,

12 inches (30 cm) above anticipated

12 inches (30 cm) above anticipated

 

porch, deck or balcony.

snow level.

snow level.

 

 

 

 

B=

Clearance to window or door that

6 inches (15 cm) for appliances < 10,000

6 inches (15 cm) for appliances < 10,000

 

may be opened.

Btuh (3 kW), 12 inches (30 cm) for

Btuh (3 kW), 9 inches (23 cm) for

 

 

appliances > 10,000 Btuh (3kW) and <

appliances > 10,000 Btuh (3 kW) and

 

 

100,000 Btuh (30kW), 36 inches (91 cm)

< 50,000 Btuh (15 kW), 12 inches

 

 

for appliances > 100,000 Btuh (30kW).

(30 cm) for appliances > 50,000 Btuh

 

 

 

(15 kW).

 

 

 

 

C= Clearance to permanently closed

*

*

 

window.

 

 

 

 

 

 

D=

Vertical Clearance to ventilated soffit

*

*

 

located above the terminal within a

 

 

 

horizontal distance of 2 feet (61 cm)

 

 

 

from the center line of the terminal.

 

 

 

 

 

 

E=

Clearance to unventilated soffit.

*

*

 

 

 

 

F=

Clearance to outside corner.

*

*

 

 

 

 

 

 

G=

Clearance to inside corner.

*

*

 

 

 

 

 

H = Clearance to each side of center line

3 feet (91 cm) within a height 15 feet

*

 

extended meter/regulator assembly.

 

(4.57 m) above the meter/regulator

 

 

above

 

 

assembly.

 

 

 

 

 

 

 

 

I =

Clearance to service regulator vent

3 feet (91 cm)

*

 

 

outlet.

 

 

 

 

 

 

J =

Clearance to nonmechanical air

6 inches (15 cm) for appliances < 10,000

6 inches (15 cm) for appliances < 10,000

 

supply inlet to the combustion air

Btuh (3 kW), 12 inches (30 cm) for

Btuh (3 kW), 9 inches (23 cm) for

 

inlet to any building or other

appliances > 10,000 Btuh (3kW) and

appliances > 10,000 Btuh (3 kW) and

 

appliance.

< 100,000 Btuh (30kW), 36 inches (91

< 50,000 Btuh (15 kW), 12 inches

 

 

cm) for appliances > 100,000 Btuh

(30 cm) for appliances > 50,000 Btuh

 

 

(30kW).

(15 kW).

 

 

 

 

K =

Clearance to mechanical air supply

6 feet (1.83 m)

3 feet (91 cm) above if within 10 feet

 

 

 

inlet.

 

(3 m) horizontally.

 

 

 

 

 

 

 

L =

Clearance above paved side walk or

Not allowed

Not allowed

 

paved driveway located on public

 

 

 

property.

 

 

 

 

 

M = Clearance under veranda, porch,

Not allowed

Not allowed

 

deck or balcony.

 

 

 

 

 

 

1 In accordance with current CAN/CGA-B149 Installation Codes.

2 In accordance with current ANSI Z223.1/ NFPA 54 National Fuel Gas Code.

+A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

*If clearances are not specified then follow local installation codes and the requirement of the gas supplier.

**For condensing appliances: The vent for this appliance shall not terminate over public walkways, near soffit vents, crawl space vents, of other areas where condensate or vapor could create a nuisance, hazard, or cause property damage. Where condensate or vapor could cause damage or could be detrimental to the operation of regulators, relief valves, or other equipment.

11