V VENT TERMINAL | X AIR SUPPLY INLET | AREA WHERE TERMINAL IS NOT PERMITTED |
Horizontal Vent Terminal Location
The following information should be used for determining the proper location of the vent terminal for direct vent tankless water heaters.
|
| Canadian Installations 1 | US Installations 2 |
A= | Clearance above grade, veranda, | 12 inches (30 cm) above anticipated | 12 inches (30 cm) above anticipated |
| porch, deck or balcony. | snow level. | snow level. |
|
|
|
|
B= | Clearance to window or door that | 6 inches (15 cm) for appliances < 10,000 | 6 inches (15 cm) for appliances < 10,000 |
| may be opened. | Btuh (3 kW), 12 inches (30 cm) for | Btuh (3 kW), 9 inches (23 cm) for |
|
| appliances > 10,000 Btuh (3kW) and < | appliances > 10,000 Btuh (3 kW) and |
|
| 100,000 Btuh (30kW), 36 inches (91 cm) | < 50,000 Btuh (15 kW), 12 inches |
|
| for appliances > 100,000 Btuh (30kW). | (30 cm) for appliances > 50,000 Btuh |
|
|
| (15 kW). |
|
|
|
|
C= Clearance to permanently closed | * | * | |
| window. |
|
|
|
|
|
|
D= | Vertical Clearance to ventilated soffit | * | * |
| located above the terminal within a |
|
|
| horizontal distance of 2 feet (61 cm) |
|
|
| from the center line of the terminal. |
|
|
|
|
|
|
E= | Clearance to unventilated soffit. | * | * |
|
|
|
|
F= | Clearance to outside corner. | * | * |
|
| ||
|
|
|
|
G= | Clearance to inside corner. | * | * |
|
| ||
|
|
| |
H = Clearance to each side of center line | 3 feet (91 cm) within a height 15 feet | * | |
| extended meter/regulator assembly. | ||
| (4.57 m) above the meter/regulator |
| |
| above |
| |
| assembly. |
| |
|
|
| |
|
|
|
|
I = | Clearance to service regulator vent | 3 feet (91 cm) | * |
| |||
| outlet. |
|
|
|
|
|
|
J = | Clearance to nonmechanical air | 6 inches (15 cm) for appliances < 10,000 | 6 inches (15 cm) for appliances < 10,000 |
| supply inlet to the combustion air | Btuh (3 kW), 12 inches (30 cm) for | Btuh (3 kW), 9 inches (23 cm) for |
| inlet to any building or other | appliances > 10,000 Btuh (3kW) and | appliances > 10,000 Btuh (3 kW) and |
| appliance. | < 100,000 Btuh (30kW), 36 inches (91 | < 50,000 Btuh (15 kW), 12 inches |
|
| cm) for appliances > 100,000 Btuh | (30 cm) for appliances > 50,000 Btuh |
|
| (30kW). | (15 kW). |
|
|
|
|
K = | Clearance to mechanical air supply | 6 feet (1.83 m) | 3 feet (91 cm) above if within 10 feet |
|
| ||
| inlet. |
| (3 m) horizontally. |
|
|
| |
|
|
|
|
L = | Clearance above paved side walk or | Not allowed | Not allowed |
| paved driveway located on public |
|
|
| property. |
|
|
|
|
| |
M = Clearance under veranda, porch, | Not allowed | Not allowed | |
| deck or balcony. |
|
|
|
|
|
|
1 In accordance with current
2 In accordance with current ANSI Z223.1/ NFPA 54 National Fuel Gas Code.
+A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
*If clearances are not specified then follow local installation codes and the requirement of the gas supplier.
**For condensing appliances: The vent for this appliance shall not terminate over public walkways, near soffit vents, crawl space vents, of other areas where condensate or vapor could create a nuisance, hazard, or cause property damage. Where condensate or vapor could cause damage or could be detrimental to the operation of regulators, relief valves, or other equipment.
11