Rheem-Ruud Tankless Heavy-Duty Gas Water Heaters
Available in 7.4 GPM Indoor and Outdoor Models
10-Year Limited Warranty on Heat Exchanger*
3-Year Limited Warranty on Parts*
•New!
maximum (additional remote control thermostats are available –
sold separately)
•New!
•Exclusive! Guardian SBT™ sensing burner technology
•Exclusive! Guardian OFW™ overheat film wrap
•Exclusive! Two
– sold separately)
•Exclusive! All Rheem tankless models are
•Exclusive! All Rheem tankless models qualify for up to a $300 federal energy tax credit (refer to your tax advisor for details)
•Exclusive! All Rheem models can be linked in up to 20 unit manifold installations by using the optional
•
•Continuous hot water
•Energy saving design
•Compact, space saving design
•Intelligent electronic controls designed to increase energy efficiency and safety
•Self diagnostic program
•Digital display shows temperature setting and maintenance codes
•
•Indoor units use Category III stainless steel vents and vent horizontally or vertically
•Indoor models supplied with a 120 volt power cord
•Environmentally friendly Low NOx burner meets SCAQMD rule 1146 requirements
•Installation vent kits available – sold separately
•Indoor and outdoor models feature freeze protection to
*See Residential Warranty Information Brochure for complete warranty information. If the water heater is installed anywhere other than a single family dwelling, such as a commercial application, or in any system in which the water is recirculated, the applicable warranty periods will be limited to three (3) years for heat exchanger; one (1) year for parts.
Energy Factor and Average Annual |
|
Operating Costs based on D.O.E. | ® |
(Department of Energy) test procedures. D.O.E. national average fuel rate natural gas 91¢/therm; LP $1.23/gallon.
|
| DESCRIPTION |
|
|
|
|
|
| FEATURES |
|
| ROUGHING IN DIMENSIONS (SHOWN IN INCHES) |
|
|
| ENERGY INFO. | |||||||
|
|
| GAS |
|
|
|
|
|
| WATER FLOW RATE |
|
|
|
|
|
| SHIP. |
|
|
| EST. ANN. | ||
|
|
| INPUT |
|
|
| TEMP. | GPM @ 77° | GPM @ 45° | CONNECTION |
|
|
|
| WEIGHT |
|
| ENERGY | OPERATING | ||||
MODEL NUMBER | BTU/HR. | TYPE | RANGE* | RISE MAX. | RISE MAX. | WATER | GAS | HEIGHT | WIDTH | DEPTH | VENT | (LBS.) |
|
| FACTOR | COST | |||||||
|
| 19,000 - | Indoor |
| 100° to | 4.3 | 7.4 | 3/4 | 3/4 | 4 | 55 | .82 | $167 Nat | ||||||||||
|
|
| 199,900 |
|
|
| 180° F |
|
|
|
|
|
|
|
|
|
|
|
| $246 LP | |||
|
| † | 19,000 - |
|
|
| 100° to |
|
|
|
|
|
|
|
|
|
|
|
| $167 Nat | |||
|
| 199,900 | Outdoor |
| 180° F | 4.3 | 7.4 | 3/4 | 3/4 | N/A | 55 | .82 | $246 LP | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| † | 19,000 - | Indoor |
|
| 100° to | 4.3 | 7.4 | 3/4 | 3/4 | 4 by 4 | 55 | .82 | $167 Nat | ||||||||
|
| 199,900 | Direct Vent |
|
| 180° F | $246 LP | ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| † Available in Natural Gas and Propane (LP). For Propane replace the N with a P when ordering. |
|
|
|
|
|
|
|
|
| ||||||||||||
|
| * Factory set maximum temperature is 120° F, capable of temperatures up to 180° F. See Use and Care Manual for setting. |
|
|
|
|
|
| |||||||||||||||
|
| • For installations above 3,280 feet a high altitude chip is required. Refer to Rheem price list or consult factory for details. |
|
|
|
|
|
| |||||||||||||||
|
| • Consult factory for information on sizing the application. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
| Installation Vent Kits available separately – |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
| Part number RTG20007 Installation Vent Kit includes 4" diameter components for a horizontal through the wall termination. |
|
|
|
|
|
| |||||||||||||||
|
| Vent Kits for Direct Vent models are listed on page 2. |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Extensive Manifold Capacity |
|
|
|
|
|
| ||||||
|
| These units are designed to meet |
|
|
|
|
|
|
|
|
|
| |||||||||||
|
| or exceed ANSI (American National |
|
|
|
|
|
|
|
|
|
| |||||||||||
|
| Standards Institute) requirements and |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| have been tested according to D.O.E. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| test procedures and meet or exceed the |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Up to 20 of the | |||||||
|
| energy efficiency requirements of |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Heavy Duty |
| |||||
|
| NAECA, ASHRAE standard 90, ICC Code |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Tankless units can |
| |||||
|
| and all state energy efficiency perform- |
|
|
|
|
|
|
|
|
|
|
|
|
|
| be linked in a |
| |||||
|
| ance criteria for energy consuming |
|
|
|
|
|
|
|
|
|
|
|
|
|
| manifold |
|
| ||||
|
| appliances. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| configuration to |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| meet the hot water |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| Before purchasing this appliance, read |
|
|
|
|
|
|
|
|
|
|
|
|
|
| needs of larger |
| |||||
|
| important energy cost and efficiency |
|
|
|
|
|
|
|
|
|
|
|
|
|
| applications. |
| |||||
|
| information available |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| from your supplier. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
In keeping with its policy of continuous progress and product improvement,
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama
P R I N T E D I N U. S . A | 1 2 / 0 6 W P | F O R M N O. 1 0 1 - 2 4 R ev. 2 |