Rheem GX90-640, GX90-550 manual Xtreme Gas continued

Models: GX90-550 GX90-640

1 4
Download 4 pages 32.96 Kb
Page 2
Image 2
Xtreme Gas continued.

Xtreme Gas continued.

DIMENSIONAL INFORMATION All Dimensions Shown in English and Metric.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WATER CONNECTIONS

 

 

APPROXIMATE

MODEL

 

 

 

A

 

B

 

C

D

 

E

 

 

F

 

 

 

G

 

 

 

 

FRONT

 

 

REAR

 

 

SHIPPING WEIGHT

NUMBER

UNITS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIDE

 

 

 

 

 

SIDE

 

 

 

STD.

 

ASME

GX90-550(A)

inches

 

74.5

 

68

 

30

 

 

25

 

10

 

 

59

 

 

 

1

 

 

 

 

 

 

 

2

 

 

 

 

 

2

 

 

 

905

 

 

945

 

 

mm

 

1892

 

1727

 

768

 

 

635

 

254

 

 

1509

 

 

 

25.4

 

 

 

 

 

 

51

 

 

 

 

 

51

 

 

 

905

 

 

945

GX90-640(A)

inches

 

74.5

 

68

 

30

 

 

25

 

10

 

 

59

 

 

 

1

 

 

 

 

 

 

 

2

 

 

 

 

 

2

 

 

 

905

 

 

945

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

 

1892

 

1727

 

768

 

 

635

 

254

 

 

1509

 

 

 

25.4

 

 

 

 

 

 

51

 

 

 

 

 

51

 

 

 

905

 

 

945

GX90-715(A)

inches

 

74.5

 

68

 

30

 

 

25

 

10

 

 

59

 

 

 

1

 

 

 

 

 

 

 

2

 

 

 

 

 

2

 

 

 

905

 

 

945

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

 

1892

 

1727

 

768

 

 

635

 

254

 

 

1509

 

 

 

25.4

 

 

 

 

 

 

51

 

 

 

 

 

51

 

 

 

905

 

 

945

GX90-500(A)

inches

 

74.5

 

68

 

30

 

 

25

 

10

 

 

59

 

 

 

1

 

 

 

 

 

 

 

2

 

 

 

 

 

2

 

 

 

905

 

 

945

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

 

1892

 

1727

 

768

 

 

635

 

254

 

 

1509

 

 

 

25.4

 

 

 

 

 

 

51

 

 

 

 

 

51

 

 

 

905

 

 

945

GX90-600(A)

inches

 

74.5

 

68

 

30

 

 

25

 

10

 

 

59

 

 

 

1

 

 

 

 

 

 

 

2

 

 

 

 

 

2

 

 

 

905

 

 

945

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

 

1892

 

1727

 

768

 

 

635

 

254

 

 

1509

 

 

 

25.4

 

 

 

 

 

 

51

 

 

 

 

 

51

 

 

 

905

 

 

945

GX90-680(A)

inches

 

74.5

 

68

 

30

 

 

25

 

10

 

 

59

 

 

 

1

 

 

 

 

 

 

 

2

 

 

 

 

 

2

 

 

 

905

 

 

945

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm

 

1892

 

1727

 

768

 

 

635

 

254

 

 

1509

 

 

 

25.4

 

 

 

 

 

 

51

 

 

 

 

 

51

 

 

 

905

 

 

945

All Models Require a 120V Power Source. (A) Suffix Indicates ASME Tank Construction Available.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM DELIVERY In U.S. Gallons and Liters. (Includes useable storage and recovery for indicated times.)

 

 

 

 

MODEL

TANK CAPACITY

INPUT BTU/HR.

TEMP.

 

 

 

 

5

 

10

15

 

 

20

 

 

30

 

45

 

 

60

 

120

 

180

Min. to Rec.

NUMBER

GALLONS

 

LITERS

 

NAT. & L.P.

 

RISE

 

UNITS

 

Min.

Min.

Min.

Min.

 

Min.

 

Min.

 

Min.

Min.

 

Min.

Contents

GX90-550(A)

90

 

 

341

 

 

550,000 NAT

 

100°F

 

GAL

 

107

 

152

196

 

241

 

 

330

 

463

 

596

 

1130

 

1663

10

 

 

 

 

 

 

 

 

 

 

 

 

 

37.7°C

 

LTR.

 

407

 

575

743

 

911

 

 

1248

 

1752

 

2257

 

4276

 

6294

 

 

 

 

GX90-640(A)

90

 

 

341

 

 

640,000 NAT

 

100°F

 

GAL.

 

115

 

166

218

 

270

 

 

373

 

529

 

684

 

1304

 

1925

9

 

 

 

 

 

 

 

 

 

 

 

 

 

37.7°C

 

LTR.

 

434

 

630

826

 

1022

 

1413

 

2000

 

2587

 

4936

 

7285

 

 

 

 

GX90-715(A)

90

 

 

341

 

 

715,000 NAT

 

100°F

 

GAL.

 

121

 

179

236

 

294

 

 

410

 

583

 

756

 

1450

 

2143

8

 

 

 

 

 

 

 

 

 

 

 

 

 

37.7°C

 

LTR.

 

457

 

676

894

 

1113

 

1551

 

2207

 

2863

 

5487

 

8111

 

 

 

 

GX90-500(A)

90

 

 

341

 

 

500,000 LP

 

100°F

 

GAL.

 

103

 

144

184

 

225

 

 

305

 

427

 

548

 

1033

 

1518

11

L.P.

 

 

 

 

 

 

 

 

 

 

 

 

37.7°C

 

LTR.

 

391

 

544

697

 

850

 

 

1156

 

1615

 

2073

 

3909

 

5744

 

 

 

 

GX90-600(A)

90

 

 

341

 

 

600,000 LP

 

100°F

 

GAL.

 

112

 

160

209

 

257

 

 

354

 

499

 

645

 

1227

 

1809

9

L.P.

 

 

 

 

 

 

 

 

 

 

 

 

37.7°C

 

LTR.

 

422

 

606

789

 

972

 

 

1340

 

1890

 

2441

 

4643

 

6845

 

 

 

 

GX90-680(A)

90

 

 

341

 

 

680,000 LP

 

100°F

 

GAL.

 

118

 

173

228

 

283

 

 

393

 

558

 

722

 

1382

 

2041

8

L.P.

 

 

 

 

 

 

 

 

 

 

 

 

37.7°C

 

LTR.

 

446

 

654

862

 

1070

 

1486

 

2110

 

2886

 

5230

 

7726

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises.

 

 

MODEL

 

INPUT BTU/HR.

 

 

THERMAL

 

 

 

40°F

 

 

50°F

 

60°F

 

70°F

 

80°F

 

90°F

 

100°F

110°F

 

120°F

130°F

140°F

NUMBER

 

NATURAL & L.P.

 

EFFICIENCY

UNITS

 

22°C

 

 

28°C

 

 

33°C

 

 

39°C

 

 

45°C

 

50°C

 

 

56°C

 

61°C

 

67°C

72°C

 

78°C

GX90-550(A)

 

550,000 NAT

 

 

80%

 

 

GPH

 

1333

 

1067

 

889

 

 

762

 

 

667

 

593

 

533

 

485

444

410

 

381

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LPH

 

5047

 

 

4037

 

3364

 

2884

 

2523

 

2243

 

2019

 

1835

1682

1553

 

1442

GX90-640(A)

 

640,000 NAT

 

 

80%

 

 

GPH

 

1551

 

1241

 

1034

 

 

887

 

 

776

 

690

 

621

 

564

517

477

 

443

 

 

 

 

 

 

 

 

 

 

 

 

 

LPH

 

5873

 

 

4698

 

3915

 

3356

 

2936

 

2610

 

2349

 

2135

1958

1807

 

1678

GX90-715(A)

 

715,000 NAT

 

 

80%

 

 

GPH

 

1733

 

1387

 

1156

 

 

991

 

 

867

 

770

 

693

 

630

578

533

 

495

 

 

 

 

 

 

 

 

 

 

 

 

 

LPH

 

6561

 

 

5249

 

4374

 

3749

 

3280

 

2916

 

2624

 

2386

2187

2019

 

1875

GX90-500(A)

 

500,000 LP

 

 

80%

 

 

GPH

 

1212

 

970

 

808

 

 

693

 

 

606

 

539

 

485

 

441

404

373

 

346

L.P.

 

 

 

 

 

 

 

 

 

 

 

 

LPH

 

4588

 

 

3670

3059

2622

2294

2039

 

1835

 

1668

1529

1412

1311

GX90-600(A)

 

600,000 LP

 

 

80%

 

 

GPH

 

1455

 

1164

 

970

 

 

831

 

 

727

 

647

 

582

 

529

485

448

 

416

L.P.

 

 

 

 

 

 

 

 

 

 

 

 

LPH

 

5506

 

 

4404

 

3670

 

 

3146

 

 

2753

 

2447

 

2202

 

2002

1835

1694

 

1573

GX90-680(A)

 

680,000 LP

 

 

80%

 

 

GPH

 

1649

 

1319

 

1099

 

 

942

 

 

824

 

733

 

659

 

599

550

507

 

471

L.P.

 

 

 

 

 

 

 

 

 

 

 

 

LPH

 

6240

 

 

4992

 

4160

 

 

3565

 

 

3120

 

2773

 

2496

 

2269

2080

1920

 

1783

Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. Recovery rate shown on the rating plate (80%) Thermal Efficiency in accordance with ANSI Z21.10.3 labeling requirements. (A) indicates available ASME model.

Page 2
Image 2
Rheem GX90-640, GX90-550 manual Xtreme Gas continued