RECOVERY CAPACITIES (80% thermal efficiency)
| MODEL | INPUT |
|
|
|
|
| GPH |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||||
| NUMBER | BTU/HR. | 40°F | 50°F | 60°F | 70°F | 80°F |
| 90°F | 100°F | 110°F | 120°F | 130°F | 140°F |
| 125,000 | 303 | 242 | 202 | 173 | 152 |
| 135 | 121 | 110 | 101 | 93 | 87 | |
| 156,000 | 378 | 303 | 252 | 216 | 189 |
| 168 | 151 | 138 | 126 | 116 | 108 | |
| 199,900 | 485 | 388 | 323 | 277 | 242 |
| 215 | 194 | 176 | 162 | 149 | 138 | |
| 199,900 | 485 | 388 | 323 | 277 | 242 |
| 215 | 194 | 176 | 162 | 149 | 138 | |
| 199,900 | 485 | 388 | 323 | 277 | 242 |
| 215 | 194 | 176 | 162 | 149 | 138 | |
| 199,900 | 485 | 388 | 323 | 277 | 242 |
| 215 | 194 | 176 | 162 | 149 | 138 | |
| 250,000 | 606 | 485 | 404 | 346 | 303 |
| 269 | 242 | 220 | 202 | 186 | 173 | |
| 250,000 | 606 | 485 | 404 | 346 | 303 |
| 269 | 242 | 220 | 202 | 186 | 173 | |
| 270,000 | 655 | 524 | 436 | 374 | 327 |
| 291 | 262 | 238 | 218 | 201 | 187 | |
| 360,000 | 873 | 698 | 582 | 499 | 436 |
| 388 | 349 | 317 | 291 | 269 | 249 | |
| 399,900 | 969 | 776 | 646 | 554 | 485 |
| 431 | 388 | 353 | 323 | 298 | 277 |
Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory.
(A) indicates available ASME model.
FIRST TIME DELIVERY (Includes useable storage and recovery for indicated times.)
|
|
|
|
| TEMP. RISE AT 100°F IN GALLONS |
| Min. |
| |||||
|
|
|
|
|
|
| |||||||
MODEL | TANK CAP. | INPUT | 5 | 10 | 15 | 20 | 30 | 45 | 60 | 120 | 180 | to Rec. |
|
NUMBER | GALLONS | BTU/HR. | Min. | Min. | Min. | Min. | Min. | Min. | Min. | Min. | Min. | Contents |
|
75 | 125,000 | 63 | 73 | 83 | 93 | 113 | 143 | 174 | 295 | 416 | 37 |
| |
82 | 156,000 | 70 | 83 | 95 | 108 | 133 | 171 | 209 | 360 | 511 | 33 |
| |
35 | 199,900 | 41 | 56 | 72 | 88 | 119 | 167 | 214 | 403 | 562 | 11 |
| |
76 | 199,900 | 69 | 86 | 102 | 118 | 150 | 199 | 247 | 441 | 635 | 24 |
| |
91 | 199,900 | 80 | 96 | 112 | 128 | 161 | 209 | 258 | 451 | 645 | 28 |
| |
100 | 199,900 | 86 | 102 | 118 | 135 | 167 | 215 | 264 | 458 | 652 | 31 |
| |
72 | 250,000 | 71 | 91 | 111 | 131 | 172 | 232 | 293 | 535 | 778 | 18 |
| |
100 | 250,000 | 90 | 110 | 131 | 151 | 191 | 252 | 312 | 555 | 797 | 25 |
| |
100 | 270,000 | 92 | 114 | 135 | 157 | 201 | 266 | 332 | 594 | 855 | 23 |
| |
65 | 360,000 | 75 | 104 | 133 | 162 | 220 | 307 | 395 | 744 | 1093 | 11 |
| |
100 | 399,900 | 102 | 135 | 167 | 199 | 264 | 361 | 458 | 846 | 1233 | 15 |
|
CLEARANCE TO COMBUSTIBLES (inches)
MODEL |
|
|
|
NUMBER | SIDE | REAR | TOP |
2 | 2 | 12 | |
2 | 2 | 12 | |
2 | 2 | 12 | |
2 | 2 | 12 | |
2 | 2 | 12 | |
2 | 4 | 12 | |
6 | 6 | 12 | |
2 | 4 | 12 | |
2 | 4 | 12 | |
6 | 6 | 12 |
6 |
| 6 | 12 | ||
OUTLET |
| H |
| INLET | |
| E |
| |||
TOP |
|
|
| TOP | |
OUTLET |
|
| T&P |
|
|
REAR SIDE | OUTLET |
|
| ||
| FRONT SIDE |
|
|
| |
|
| C |
|
|
|
|
| INLET |
|
|
|
|
| FRONT SIDE |
|
| |
|
|
|
|
| F B A |
SYSTEM |
|
|
|
|
|
SENTINEL |
|
|
|
|
|
G | INLET |
|
|
| |
REAR SIDE |
|
| D | ||
|
|
|
|
| |
7" |
|
|
|
|
|
(178mm) |
|
|
|
|
|
DIMENSIONS (Inches) |
|
|
|
|
|
|
|
|
|
|
|
| |
| A | B | C | D | E | F | G | H | WATER CONNECTIONS | APPROXIMATE | |||
MODEL | TOP | FRONT | REAR | SHIPPINGWEIGHT | |||||||||
NUMBER | IN/OUT | SIDE | SIDE | STD. | ASME | ||||||||
61 | 25 | 5 | 56 | 3/4 | 20 | 480 lbs. | N/A | ||||||
64 | 25 | 6 | 3/4 | 20 | 490 lbs. | N/A | |||||||
25 | 6 | 3/4 | 20 | 405 lbs. | N/A | ||||||||
64 | 25 | 6 | 3/4 | 20 | 540 lbs. | N/A | |||||||
6 | 3/4 | 20 | 600 lbs. | N/A | |||||||||
6 | 3/4 | 23 | 2 | 2 | 780 lbs. | 835 lbs. | |||||||
25 | 6 | 3/4 | 20 | 590 lbs. | 630 lbs. | ||||||||
6 | 3/4 | 23 | 2 | 2 | 795 lbs. | 835 lbs. | |||||||
6 | 3/4 | 23 | 2 | 2 | 805 lbs. | 845 lbs. | |||||||
25 | 8 | 3/4 | N/A | N/A | 640 lbs. | 680 lbs. | |||||||
76 | 8 | 1 | 23 | 2 | 2 | 770 lbs. | 810 lbs. |
All Models Require a 120V /1.5 Amp Power Source. (A) Suffix Indicates ASME Tank Construction Available.
Recommended specifications(for trade reference only)
Water heater(s) shall be UNIVERSAL model ________________, manufactured by
100°F temperature rise when tested and certified at ____________ thermal efficiency.Water heater(s) shall have a storage capacity of _________ gallons. Water heater(s) shall have the CSA
seal of certification and supplied with a factory installed AGA/ASME rated temperature and pressure relief valve. Tank(s) shall be furnished with a tube bundle having a double coating of high temperature porcelain enamel and furnished with magnesium anode rods rigidly supported. Water heater(s) shall meet or exceed the thermal efficiency and standby loss requirements of ASHRAE Standard
inputs less than 360,000 Btu/hr. shall have top, front and rear side inlet/outlet water connections.Water heater(s) shall be covered by a three year limited warranty against tank leaks.
•Add for ASME construction – Water heater(s) shall be constructed in accordance with the requirements of the ASME
Boiler and Pressure Vessel Code, Section IV Part HLW.
LimitedWarranty
This product features a three year limited warranty against tank leaks. Please refer to Commercial Warranty Information brochure for complete warranty information.
In keeping with its policy of continuous progress and product improvement,
Rheem Water Heaters • 101 Bell Road, Montgomery, Alabama
PRINTED IN U.S.A | 05/07 WP | Form No. |