Rheem PH20R-(IFSN)(IFSP)(OFN)(OFP), PTG2-42(PVN)(PVP) Vent Horizontal Wall Thimble Installation

Models: RUTG2-42(PVN)(PVP) RUTG2-53-(PVN)(PVP)(XN)(XP) RTG2-53-(PVN)(PVP)(XN)(XP) PH-16(FISN)(FISP) RMTG2-53-(PVN)(PVP)(XN)(XP) RMTG2-42(PVN)(PVP) PH20R-(IFSN)(IFSP)(OFN)(OFP) RTG2-42(PVN)(PVP) PTG2-42(PVN)(PVP)

1 36
Download 36 pages 62 Kb
Page 14
Image 14

Installing the water heater:

Vent Horizontal Wall Thimble Installation

Inner Thimble

Outer Thimble

Section

Section

Side View

An approved 3 inch (7.6 cm) Vent Horizontal Wall Thimble must be used.

The Wall Thimble requires mechanical support from the wall sufficient to support any incidental loads on the system. If the wall is not sufficient enough to support the Wall Thimble, then appropriate additional framing and/or blocking is required.

sheathing is particle board or other composite material. Use four (4) #10x1-1/4” wood screws for plywood, solid wood sheathing or members. Use suitable masonry anchors when passing through solid masonry walls. Reinstall the decorative sheathing around the Wall Thimble. This assembly may be painted to match the exterior decor.

 

 

Inner Wall

 

 

 

 

 

 

 

Outer Thimble

 

Inner Thimble

 

 

Section

 

Section

 

 

 

90˚ Elbow

 

 

 

 

 

Vent

 

 

 

 

 

 

 

 

Pipe

 

 

90˚ termination

 

 

Outer

 

 

 

 

Wall

 

 

with screen

Appliance

 

 

 

Vent Adapter

 

Caulk for

 

 

 

 

 

 

 

weather seal

 

 

 

 

 

 

Water

Heater

Outside Wall

Mounting

Brackets

Side View

Side View

WARNING: Use UL approved Category III vent material only. No other vent material is permitted.

INSTALLATION PROCEDURE: Prepare an opening for the Wall Thimble in the wall. The opening must be 6-1/2” (16 cm) in diameter for a 3” (7.6 cm) vent system.

If there are not sufficient support members to secure the Wall Thimble or if there is a semirigid foam insulation layer under the sheathing, appropriate fasteners must be used to secure the Wall Thimble to the support members.

The Wall Thimble is designed to adapt to any wall thickness from 3-1/2” (9 cm) to 6” (15 cm) thick. If the wall is thicker than 6” (15 cm), the Wall Thimble may be extended using a piece of 6” (15 cm) diameter snaplock or welded seam galvanized pipe up to 6” (15 cm) long.

Select the larger diameter half of the Wall Thimble for the outside of the wall.

Apply a continuous bead of high quality silicone or silicone/latex caulk on the inside of the outer flange. This will be the only weather seal to keep moisture outside the building. Ensure a sufficient seal is made.

Attach a Rheem approved 3” (7.6 cm)

screened, 90° elbow termination to the

female end of a vent section or slip

connector. Use the method described in the

Venting installation instructions provided

with the vent. Slide the vent in through the

outside of the Thimble and seal the annular

space with a thick bead of caulk.

Slide the interior portion of the Thimble

into the inside hole. Be certain the interior

and exterior Thimble halves overlap at least

1” (2.5 cm). If insufficient overlap exists,

extend the interior portion with single wall

galvanized pipe.

Secure the Wall Thimble to the interior

sheathing using suitable fasteners.

Secure the vent section or slip connector

that protrudes through the Wall Thimble

to the rest of the vent system as described

in the Venting installation instructions

provided with the vent.

Proper support must be provided for the

vent pipes as mentioned in the venting

section.

CAUTION: Follow the vent manufacturer’s installation instructions as design might vary from manufacturer to manufacturer.

Position this portion of the Wall Thimble into the prepared hole from the outside. Secure the assembly into the prepared opening using fasteners as indicated by sheathing or structural members, sealing the screw heads with more caulking.

Use four (4) hollow wall anchors, at least 1/8” (.32 cm) in diameter and of appropriate length for the thickness of the sheathing, if

Support method used should isolate the

vent pipe from floor joist or other structural

members to help prevent the transmission

of noise and vibration.

Do not support, pin or otherwise secure the

venting system in a way that restricts the

normal thermal expansion and contraction

of the chosen venting material.

 

1/4" per foot downward slope

 

 

 

1/4" per foot upward slope

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3" (8 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3" (8 cm) Clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clearance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2'

 

 

 

 

 

 

 

 

 

 

 

2'

 

 

 

 

 

 

 

 

Support

 

(61 cm)

 

 

 

 

 

 

(61 cm)

 

 

 

 

 

 

 

Support

 

 

 

 

 

Hanger

 

Max

 

 

 

Max

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hanger

 

 

 

 

 

 

 

 

 

Condensate Trap

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent

To Drain. Dispose of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent

 

 

 

 

 

 

 

 

condensate in accordance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adapter

with local codes

 

 

 

 

 

 

 

Adapter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example A: Typical Horizontal Termination

Example B: Typical Horizontal Termination

w/ 1/4” per foot DOWNWARD Slope

w/ 1/4” per foot UPWARD Slope

14

Page 14
Image 14
Rheem PH20R-(IFSN)(IFSP)(OFN)(OFP), PTG2-42(PVN)(PVP), PH-16(FISN)(FISP) warranty Vent Horizontal Wall Thimble Installation

RUTG2-42(PVN)(PVP), RUTG2-53-(PVN)(PVP)(XN)(XP), RTG2-53-(PVN)(PVP)(XN)(XP), PH-16(FISN)(FISP), RMTG2-53-(PVN)(PVP)(XN)(XP) specifications

Rheem’s innovative line of tankless water heaters, including the PTG2-42(PVN)(PVP), RTG2-42(PVN)(PVP), PH20R-(IFSN)(IFSP)(OFN)(OFP), RMTG2-42(PVN)(PVP), and RMTG2-53-(PVN)(PVP)(XN)(XP), represents a significant advancement in residential and commercial water heating technologies. These models are designed to deliver hot water on demand, ensuring efficiency and convenience while minimizing energy consumption.

One of the standout features of these Rheem models is their energy efficiency. Employing advanced condensing technology, they are capable of converting up to 98% of the energy consumed into hot water. This impressive efficiency reduces utility bills and makes them an environmentally friendly choice compared to traditional tank water heaters.

The PTG2 and RTG2 series are particularly versatile, accommodating various installation needs. Their compact design allows for both indoor and outdoor installation, making them ideal for homes with limited space. Additionally, they are equipped with a multiple venting option, which provides flexibility in installation locations.

The PH20R series incorporates Rheem’s proprietary modeling and simulation technologies to optimize performance. These models feature enhanced safety functions and user-friendly digital controls, allowing homeowners to easily set and monitor their water temperatures. The ease of use extends to maintenance as well, as many components are accessible for routine checks and cleaning.

Another significant advantage of the RMTG2 models is their integrated Wi-Fi connectivity, enabling users to manage their water heating systems remotely through Rheem’s mobile app. This smart technology provides real-time data, alerts, and allows for temperature adjustments, ensuring that users always have hot water when they need it.

Rheem’s tankless water heaters also boast a robust warranty, a testament to their durability and reliability. With options that cater to various household sizes and hot water needs, these models can provide continuous hot water for homes with multiple bathrooms and heavy consumption.

For those seeking cost-effective, efficient, and smart water heating solutions, the Rheem PTG2, RTG2, PH20R, RMTG2-42, and RMTG2-53 series stand out as top contenders in the market. Their combination of advanced technology, energy savings, and user-friendly features position them as industry leaders, providing long-term benefits for any homeowner.