• Insulation – sag and moisture proof fiberglass
insulation surrounds the storage tank to mini-
mize heat loss. In addition, heavy mineral wool
insulation surrounds the combustion chamber.
• Anode rods – patented design utilizes multiple
magnesium rods to ensure long life and corro-
sion resistance.
• Temperature and pressure relief valve –
AGA/ASME rated and factory installed.
• Hand-hole cleanout – for removal of lime/sedi-
ment deposits.
• Manual reset high limit – all ASME models are
factory equipped with a manual reset high limit
to meet the code requirements of many states.
• Gas control system – Fully adjustable
thermostat from 100°F to 180°F, 24 volt
combination gas valve includes main gas
pressure regulation, On-Off manual valve,
120/24 volt transformer, and high limit
temperature cut-out.
• Stainless steel burners – Precision burners
of raised port design are formed from high
chromium stainless steel. Entire burner
assembly is built like a drawer which slides
out easily for quick inspection and simple
maintenance.
• LED dIagnostics – On damper assembly for
easier service.
Recommended Specifications (for trade reference only)
Water heater(s) shall be UNIVERSAL model ________________, manufactured by RHEEM-RUUD,
having gas input of __________ Btu/hr.and a recovery rate of _____________ GPH at a 100°F tem-
perature rise when tested and certified at ____________ thermal efficiency.Water heater(s) shall have
a storage capacity of _________ gallons.Water heater(s) shall have the CSA seal of certification and
supplied with a factory installed AGA/ASME rated temperature and pressure relief valve.Tank(s) shall
be furnished with a tube bundle having a double coating of high temperature porcelain enamel and fur-
nished with magnesium anode rods rigidly supported. Water heater(s) shall meet or exceed the thermal
efficiency and standby loss requirements of ASHRAE.Tanks shall have a working pressure rating of
150 psi, and shall be completely factory assembled, including a pressure regulator properly adjusted for
operation on ___________ gas with stainless steel burners. Controls will be arranged for safety shutoff
in event of pilot failure.Water heater(s) with inputs less than 360,000 Btu/hr. shall have top, front and
rear side inlet/outlet water connections.Water heater(s) shall be covered by a three year limited
warranty against tank leaks.
• Add for ASME construction –
Water heater(s) shall be constructed in accordance with the requirements of the ASME Boiler and
Pressure Vessel Code, Section IV Part HLW.
Limited Warranty
This product features a three year limited warranty against tank leaks.Please refer to Commercial
Warranty Information brochure for complete warranty information.
COMMERCIAL
WATER HEATERS
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
Rheem Canada Ltd./Ltée,128 Barton Street West, Hamilton, Ontario L8N 3P3
PRINTED IN U.S.A 05/06 WP FORM NO. RR102C-1 Rev.16
In keeping with its policy of continuous progress and product improvement,Rheem-Ruud reserves the right to make changes without notice.
Other Features:
Universal Gas continued.