EX22 (RHFE-558RWTA)
Safety Devices
Venting
Maximum Vent Length
Wall Thickness and Flue Manifold Kits
(the “A” vent kit is included with the appliance)
Warranty
•Flame rod detects flame failure; results in auto shutdown to prevent escape of gas
•
•3 amp fuse protects against power surge; results in auto shutdown
•Abnormal spark at time of ignition results in auto shutdown
•Combustion fan purges any gas from the combustion chamber before ignition
•Convection fan continues to run after burner shutdown to cool internal parts
•Function lock prevents inadvertent operation
•Appliance shuts down if room reaches 104° F (40° C)
concentric; 3 1/8 inch (80 mm) wall hole
13 feet (4 m) with a maximum of 2 bends; maximum 8 feet (2.4 m) vertically
Name | Kit No. |
| fits walls |
S Vent Kit | 3 | - 4 1/2 in (75 - 115 mm) | |
A Vent Kit | 4 | 1/2 - 9 1/2 in (115 - 240 mm) | |
B Vent Kit | 9 | 1/2 - 15 3/4 in (240 - 400mm) | |
C Vent Kit | 15 3/4 - 23 5/8 in (400 - 600 mm) | ||
D Vent Kit | 23 5/8 - 31 1/2 in (600 - 800 mm) |
Labor: 2 years; Parts: 5 years; Heat Exchanger: 10 years with years
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS
6 1/2" (165mm) | 3 3/8" (85mm) | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 •