Extension Kit Installation

Clearances

exhaust pipe to combustibles

1 inch (25.4 mm)

 

 

exhaust pipe to non-combustibles

zero

 

 

 

 

 

 

Clamps

 

Exhaust pipe

Both the exhaust line and air intake hose are

 

 

 

supported by clamps which are attached to the wall.

 

 

 

A wall fixture can be used to offset the clamp from the

 

 

 

wall. Use Screw B to attach the wall fixture to the

 

 

 

wall. If the wall fixture is not used then use Screw A

 

 

 

 

 

 

and the nut to attach the clamp to the wall.

 

 

 

 

 

 

The air intake hose should always be underneath the

 

 

 

exhaust line so that in case the air intake hose sags it

 

 

 

will not come into contact with the exhaust line.

 

 

 

 

 

Air intake hose

Exhaust pipe

Air intake hose

Installing the Exhaust Line

The exhaust line is connected between the bent pipe at the rear of the heater and the exhaust port on the flue manifold.

To connect exhaust pipes with other straight pipes or bends, fit the male end into the female end. Use pipe stopper A to clamp the connection.

Use pipe stopper B to fix the length on the adjustable exhaust pipes. Do not extend these pipes beyond the red line.

Do not cut the exhaust pipe. Use the adjustable pipes if necessary.

To bend the elbow, insert exhaust pipes into both ends for additional leverage. Bend to desired angle.

Do not straighten the bent pipe attached to the appliance.

Connecting the Air Intake Hose

The air intake hose is connected between the air connection at the rear of the heater and the air intake port on the flue manifold.

Push the air intake hose onto the flue manifold and secure with the plastic cable tie.

Join air intake hoses by screwing the hose joint half of its length into the air intake hose and then screwing another air intake hose into the hose joint.

Male end

Female end

Pipe stopper B

 

Pipe stopper A

Adjust the angle

The lengths of the air intake hose and the exhaust pipe must be the same in order for the appliance to operate properly. The hose can be cut to the required length. Deburr all rough edges. Do not cut the hose attached to the appliance.

Support the air intake hose with pipe clamps. Hose joint

Air intake hoses

Rinnai Corporation EX17C / EX22C Manual

25

Page 25
Image 25
Rinnai EX17C (RHFE-434FTA) Clearances, Clamps, Installing the Exhaust Line, Connecting the Air Intake Hose

EX17C (RHFE-434FTA), EX22C (RHFE-559FTA) specifications

The Rinnai EX17C (RHFE-434FTA) and EX22C (RHFE-559FTA) are innovative wall-mounted gas heaters that provide efficient and cozy heating solutions for indoor spaces. Manufactured with advanced technology, these models are designed to meet diverse heating needs while ensuring user comfort and safety.

One of the standout features of both the EX17C and EX22C is their energy efficiency. With a high energy star rating, these heaters minimize energy consumption, making them ideal for environmentally conscious consumers. The EX17C can deliver an impressive 17 kW of heating power, while the EX22C offers up to 22 kW, accommodating various room sizes and layouts effectively.

Both models utilize Rinnai’s advanced direct vent technology. This system allows fresh air from outside to be used for combustion, ensuring optimal heating performance without depleting indoor oxygen levels. This feature not only enhances comfort but also contributes to improved indoor air quality. Additionally, the closed combustion system ensures that exhaust gases are safely vented outside, providing a safer environment for occupants.

In terms of design, the EX17C and EX22C are sleek and modern, fitting seamlessly into various interior styles. Their wall-mounted configuration saves floor space, making them suitable for smaller rooms or homes where space optimization is a priority. The adjustable heat settings enable users to customize their heating preferences according to the season or personal comfort levels.

User convenience is a core aspect of both models, which come equipped with an intuitive electronic control panel. This feature allows for easy temperature adjustments and scheduling, ensuring that optimal heat levels can be maintained without constant manual intervention. Some models also offer remote control capabilities, enhancing usability for consumers.

Safety is paramount in Rinnai's design philosophy, and the EX17C and EX22C include multiple safety features such as flame failure detection and automatic shut-off. These mechanisms ensure that any irregularities in operation are promptly addressed, providing peace of mind for homeowners.

In conclusion, the Rinnai EX17C and EX22C offer modern, energy-efficient heating solutions with advanced technology, user-friendly features, and a focus on safety. These models are ideal choices for anyone looking to enhance their indoor heating experience while maintaining energy efficiency and comfort.