18 Rinnai Corporation RHFE-750ETR
Do not vent the exhaust into ‘natural draft’ flue pipes
or a chimney flue.
The enclosure must be within these limits:
The front panel extends below the surface on which
the appliance rests. Ensure that clearance is
maintained in order to install the front panel.
Width (w) 33.8 in (860 mm)
Height (h) 26.0 - 26.2 in (660-665 mm)
Depth (d) 15.0 - 16.9 in (380-430 mm)
Enclosure Dimensions
For installation in the corner of the room refer to the
diagram at the right and the table below for
dimensions. These dimensions are the minimum
required if using the minimum width, height, and
depth dimensions above.
Enclosure Dimensions in a Corner
x 63.8 in (1620 mm)
y 45.1 in (1146 mm)
z 31.9 in (810 mm)
Location
This appliance has a cool outer casing that allows it to
be installed in a recessed application consisting of
combustible materials such as wood and plaster.
The location needs to have a level surface that allows
the appliance to be rolled in or out of the enclosure.
If the surface is elevated and there is not enough
room for it to be rolled out then a base and joists may
be used as shown.
The appliance will have to be rolled out for
maintenance. After installation do not place any
permanent fixtures that would prevent pulling the
appliance out for access. To pull the appliance
completely out of the enclosure a minimum of 15
inches from the front panel would be needed.
wdhxy
z
JOIST JOIST
RIGHT
WHEEL
LEFT
WHEEL