![RU80e (KB2530WD)](/images/new-backgrounds/38309/383091x1.webp)
RU80e (KB2530WD)
Type of Appliance
Rinnai model number Operation / Installation Minimum/Maximum Gas Rate (Input) Electrical
Electrical Consumption
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Approved Gas Types
Energy Factor (EF)
Service Connections
Isolation & Pressure Relief Valves Included
Water Flow Control
Minimum/Maximum Water Supply Pressure
Condensing, Tankless, Temperature controlled, continuous flow, gas hot water system, Energy Star Qualified
Forced combustion; outdoor only
15,200 - 152,000 BTU/h |
|
Appliance: | AC 120 Volts - 60 Hz |
Temperature Controller: | DC 12 Volts |
Normal: 41 w Standby: 2 w | |
Direct electronic ignition |
|
Minimum flow rate: 0.26 GPM
Minimum activation flow rate: 0.4 GPM
Maximum flow rate: 8.0 GPM
98° - 120° F (factory default) Maximum temperature is selectable at 120° F or at 140° F; 98° - 185° F available with the
120° F (factory default) or 140° F
Natural or Propane (ensure unit matches gas type)
Natural Gas: 0.96 | Propane: 0.96 |
Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT
Heavy duty forged brass Webstone Isolator valves EXP E2, certified to NSF/ANSI
Water flow sensor, electronic water control and
15 - 150 PSI (50 PSI or above is recommended for maximum flow)
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
FLOW TABLE
Water Flow (gpm)
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
0 | 25 | 50 | 75 | 100 | 125 | 150 |
delta T - Temperature Rise (ºF)
© 2012 Rinnai Corporation | RU80e SP | 3/2012 |