Remote Panel Descriptions
Basic Remote | Standard Discharge Control | Deluxe Temperature Control | ||
|
| Remote (SDC) | Remote (DTC) | |
This control is used for | This control is used for | This control is used for | ||
and space heating. The discharge | day/night heating of the building. The | and total automatic “day/night” heating | ||
temperature of the heater remains | discharge temperature of the heater | of the building. A | ||
constant as selected on the selection | remains constant as selected on the | ing room Selectrastat fully modulates | ||
dial. The burner flame is modulated | selection dial. The burner flame is | the burner flame to maintain space | ||
by a discharge temperature control, | modulated by a discharge temperature | temperature and compensate for | ||
which is governed by the remote | control, which is governed by the | changing building heat losses or | ||
temperature selector. | remote temperature selector. | gains. | ||
|
| |||
FAN ON/BURNER ON mode: | AUTO/WINTER mode: | AUTO/WINTER mode: | ||
Heater cycles on/off to maintain space | Occupied time: Heater can operate | |||
Heater can operate continuously for | ||||
temperature as selected on the | continuously fully modulating Btu/h | |||
building exhaust air replacement and | ||||
thermostat. | output to maintain space temperature | |||
space heating by maintaining a | ||||
| as selected on the Selectrastat. | |||
constant discharge temperature. |
| |||
ON/WINTER mode: | Unoccupied time: Heater cycles on/ | |||
|
| |||
FAN ON/BURNER OFF mode: | Heater can operate continuously for | off to maintain space temperature as | ||
The blower can operate without the | building exhaust air replacement and | selected on the programmable ther- | ||
space heating by maintaining a constant | mostat | |||
burner for summer ventilation. | ||||
discharge temperature. | (night setback). | |||
|
| |||
NEMA 1 enclosure. | ON/SUMMER mode: | ON/WINTER mode: | ||
|
| |||
|
| The blower can operate without the | Heater can operate continuously fully | |
|
| burner for summer ventilation. | modulating Btu/h output to maintain | |
|
|
| space temperature as selected on the | |
|
| NEMA 1 enclosure. | Selectrastat. | |
|
|
| ON/SUMMER mode: | |
|
|
| The blower can operate without the | |
|
|
| burner for summer ventilation. | |
|
|
| NEMA 1 enclosure. | |
|
|
|
|
Installation Code and Annual Inspections:
All installations and service of ROBERTS GORDON® equipment must be performed by a contractor qualified in the installation and
service of equipment sold and supplied by
Further Information: Applications, engineering and detailed guidance on systems design, installation and equipment performance is available through ROBERTS GORDON® representatives. Please contact us for any further information you may require, including the Installation, Operation and Service Manual.
This product is not for residential use.
This document is intended to assist licensed professionals in the exercise of their professional judgement.
European Office: | |
1250 William Street | Roberts Gordon Europe Limited |
P.O. Box 44 | Telephone: +44 (0)121 506 7700 |
Buffalo, NY | Fax: +44 (0)121 506 7701 |
Telephone: 716.852.4400 |
|
Fax: 716.852.0854 |
|
Toll Free: 800.828.7450 |
|
| |
© 2008 | All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form |
| or by any means – graphic, electronic, or mechanical, including photocopying, recording, taping, or information |
| storage and retrieval systems – without written permission of |
Printed in U.S.A. | C2RPBNA | 1008 Rev A |