Features/Benefits of the Vantage® II
Setting the Standard in Unitary Infrared Heating
Feature | Benefit |
Layout & Installation: |
|
Design based on over 30 years of infrared heating experience | |
Broad range of high BTUH input burners and tube lengths; straight, | Fits any building size or floor plan |
"U" or "L" configurations available |
|
Reflectors can be tilted or side reflectors can be added | Concentrates heat where needed |
Designed to readily accept low voltage thermostats | Reduces installation cost – no additional transformer required for |
| single heater installation. |
Quick assembly stainless steel couplings | Minimizes installation time |
Standard flue connector | Easy vent installation |
Option of decorative grille for drop ceiling applications | |
Operation: |
|
Operates with natural gas or LP gas (propane) | Fuel efficient and environmentally friendly |
Honeywell® SmartValve® II control | Combines the gas valve and electronic ignition control functions |
| into one single unit |
Hot surface electronic ignition control | Reliable |
Prepurge and timed trial for ignition with multiple ignition trial | Reduces nuisance lockouts |
Auto reset from lockout | Resets the system after one hour of lockout and begins another |
| sequence for ignition |
Warms people and objects directly, not the air | |
Maximizes energy reflection; minimizes heat loss by convection | |
Safety: |
|
SmartValve® II control provides all gas ignition safety functions | Controls gas flow, ignition source and combustion air blower and |
| monitors pressure switch |
CSA design certified | Independent testing to industry standards |
Electrical and burner components separated by a partition | Minimizes negative effects of contaminants and back draft |
Stainless steel flex gas connector included | Reliable, durable gas piping |
Door interlock switch | Halts burner operation for service |
Detailed Installation, Operation and Service manual | Reduces installation time and errors; easier to troubleshoot and |
| repair |
Maintenance: |
|
Diagnostic capability incorporated in burner design | Reduces service time |
Separate burner compartment | Protects valuable electrical controls from heat exposure and |
| extends life of componentry |
Durable, spot welded burner construction with electrostatically | Strong, |
applied paint |
|
Removable burner doors | Easy access for service |
Mica flame observation window | Flame verification and burner operation easy to observe |
No hidden |
1250 William Street | 76 Main Street West |
P.O. Box 44 | Unit 10 |
Buffalo, New York | Grimsby, Ontario L3M 1R6 |
Telephone: 716.852.4400 | Telephone: 905.945.5403 |
Fax: 716.852.0854 | Fax: 905.945.0511 |
Toll Free: 800.828.7450 |
|
|
CTH2FBNA | Printed in USA | 06/02 |