Rockford Fosgate 100ix, 40ix, 60ix Diagnosis, Symptom, Remedy, Speaker Output, Low or Distorted

Models: 100ix 200ix 60ix 40ix

1 36
Download 36 pages 62.56 Kb
Page 27
Image 27

Symptom

Diagnosis

Remedy

 

 

 

 

 

Speaker Output

Input gain signal for

Readjust input gains of

 

Low or Distorted

amplifier is incorrectly

amplifier.

 

 

set.

 

 

 

 

 

 

 

Source unit output too

Check system with known

 

 

low or source unit has

working source and repair

 

 

no output.

or replace original source

 

 

 

as needed.

 

 

 

 

 

 

XCard is missing or not

Check XCard position and

 

 

placed properly in cross-

repair or replace as neces-

 

 

over slots.

sary.

 

 

 

 

 

 

Low battery voltage or

Check the alternator, bat-

 

 

large voltage drops to

tery, fuse, and power and

 

 

the amplifier under load.

ground wiring. Repair as

 

 

 

necessary.

 

 

 

 

 

Amplifier Noise

Voltage spike from out-

Disconnect input signal to

 

(Turn-on Pop)

put of preceding com-

amplifier and turn ampli-

 

ponent is entering am-

fier on and off. If noise is

 

 

 

 

plifier through input sig-

eliminated, connect REM

 

 

nal.

lead of amplifier to source

 

 

 

unit with a delay turn-on

 

 

 

module.

 

 

 

 

 

 

Voltage spike from re-

Use a different 12 volt

 

 

mote turn-on lead is

source for REM lead of

 

 

entering through REM

amplifier. (i.e., battery di-

 

 

input terminal.

rect) If noise is eliminated,

 

 

 

use a relay to isolate am-

 

 

 

plifier from noisy turn-on

 

 

 

output.

 

– 23 –

Page 27
Image 27
Rockford Fosgate 100ix, 40ix, 60ix, 200ix Diagnosis, Symptom, Remedy, Speaker Output, Low or Distorted, Amplifier Noise