Rockford Fosgate PUNCH 4020 DSM Diagnosis, Symptom, Remedy, Speaker Output, Low or Distorted

Models: PUNCH 4020 DSM

1 28
Download 28 pages 23.44 Kb
Page 22
Image 22

 

Symptom

Diagnosis

Remedy

 

 

 

 

 

 

Speaker Output

Input gain signal for

Readjust input gains of

 

Low or Distorted

amplifier set too low.

amplifier.

 

 

 

 

 

 

 

 

Source unit output too

Check system with known

 

 

 

low.

working source and repair

 

 

 

 

or replace orignal source as

 

 

 

 

needed.

 

 

 

 

 

 

 

 

Speakers wired out of

Check speaker polarity and

 

 

 

polarity from the left to

correct as needed.

 

 

 

right channel.

 

 

 

 

 

 

 

 

 

XCards are missing or

Check signal input switch

 

 

 

not placed properly in

and XCard positons and

 

 

 

crossover slots and/or

repair or replace as neces-

 

 

 

switch not properly se-

sary.

 

 

 

lected.

 

 

 

 

 

 

 

 

 

Low battery voltage or

Check the alternator, bat-

 

 

 

large voltage drops to

tery, fuse and wiring and

 

 

 

the amplifier under load.

repair as necessary.

 

 

 

 

 

 

Amplifier Noise

Voltage spike from out-

Disconnect input signal to

 

(Turn-on Pop)

put of preceding com-

amplifier and turn ampli-

 

ponent is entering am-

fier on and off. If noise is

 

 

 

 

 

 

plifier through input sig-

eliminated, connect REM

 

 

 

nal.

lead of amplifier to source

 

 

 

 

unit with a delay turn-on

 

 

 

 

module.

 

 

 

 

 

 

 

 

Voltage spike from re-

Use different 12 volt

 

 

 

mote turn-on lead is

source for REM lead of

 

 

 

entering through REM

amplifier. (i.e., battery di-

 

 

 

input terminal.

rect) If noise is eliminated,

 

 

 

 

use relay to isolate ampli-

 

 

 

 

fier from noisy turn-on

 

 

 

 

output.

 

 

 

 

 