Rolls PS16 Personal Monitor, Power Center, Introduction, Features, Description, Specifications

Models: PS16

1 2
Download 2 pages 56.56 Kb
Page 2
Image 2
INTRODUCTION

INTRODUCTION

Thank you for your purchase of the PS16 Personal Monitor Power Center. The PS16 supplies the DC power and distributes the Monitor signal to up to ten of the PM50s, the PM50sOB, and the PM350 units. This dramati- cally increases efficiency and eliminates the need for multiple wall-warts and adapter cables.

The power AND monitor signal are carried from each PS16 output using an ordinary 1/4" stereo cable to the Monitor input of the PM50s, sOB, and

350.Using stereo “Y” adapters, up to ten of the Personal Monitor Amplifi- ers may be daisy-chained.

NOTE: Older PM50s and PM50sOB units may need a slight modification in order to operate with the PS16. Any PM50s or PM50sOB WITHOUT a ground lift jumper and mono/stereo jumper will need this modification. Call the factory at (801) 263-9053 for details.

FEATURES

-Supplies power for up to ten PM50s, PM50sOB, and PM350 units.

-Directly supplies a monitor signal to four of the above units, indirectly (by using stereo “Y” adapters) will provide signal for up to ten units.

-Unbalanced 1/4" and TRANSFORMER-balanced XLR inputs.

DESCRIPTION

LINE INPUTS

UNBALANCED: 1/4' Tip-Sleeve jack. Connects to a mixer's unbalanced

Monitor or Auxiliary Send.

 

 

 

 

 

 

BALANCED: Transformer isolated

 

 

 

 

 

 

 

 

 

 

 

12VAC

female XLR jack.Connects to a mixer's

 

unbal

 

balanced

 

 

LINE INPUTS

 

+

balanced Monitor or Auxiliary Send.

 

 

 

 

 

 

 

-

12VAC: Connects to the included Rolls

 

PERSONAL MONITOR

PS12 power adapter.

 

 

POWER CENTER

PS16

 

 

 

 

power

 

 

 

 

OUT 1 - 4: 1/4" Tip-Ring-Sleeve jacks.

 

status

 

 

 

 

 

 

WARNING:

 

 

The Tip of the connector contains the

 

 

THIS UNIT MAY BE DAMAGED IF THE LIGHT IS OFF

 

 

WHEN POWER IS APPLIED - IMMEDIATELY UNPLUG

 

 

ALL OUTPUTS. USE TIP-RING-SLEEVE PLUGS ONLY.

audio signal, the Ring has the 12 volts

 

 

 

 

 

 

DC required to operate the Personal

 

 

 

 

 

 

Monitor devices, and the Sleeve con-

 

 

 

 

 

www.rolls.com

 

 

 

 

 

nects to ground.

 

OUT 1

 

OUT 2

OUT 3

OUT 4

 

 

 

 

 

 

 

 

 

 

CONNECTION / OPERATION

Connect the Send of the mixer to the appropriate Input of the PS16 (balanced or unbalanced).

Connect the PS12 adapter to the 12VAC input of the PS16. The Power/ Status LED should light. If not, immediately unplug the power as this indicates a short from the Ring of an Output jack to ground.

Connect the TIP-RING-SLEEVE STEREO cables from the PS16 Outputs to the PM series Monitor Inputs. Refer to the Personal Monitor unit owners manual for proper operation of that unit.

FOR APPLICATION DIAGRAMS, VISIT OUR WEBSITE AT WWW.ROLLS.COM.

SPECIFICATIONS

 

Input Power:

12 VAC, 700 mA

Output Power:

12 VDC on the Ring terminal of each OUT jack.

Size:

3.125" x 3.125" x 1.25"

Weight:

1 lb (.45 Kg)

 

 

 

 

 

 

 

 

 

SCHEMATIC

 

 

 

 

 

 

 

 

PHONE 1/4

 

 

 

 

XLR JACK M

 

 

 

 

 

 

 

J1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

T1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J11

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XFMR AUDIO

 

 

 

 

 

J2

LOW OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHONE 1/4

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

J2

 

 

 

 

 

 

 

J3

 

 

 

 

PHONE 1/4

 

 

 

 

 

 

 

HIGH OUT

 

 

 

 

 

 

 

 

 

 

 

PHONE 1/4

 

 

 

 

 

 

 

 

 

 

 

J4

 

 

 

 

 

 

 

 

 

 

 

 

PHONE 1/4

 

 

 

 

 

 

 

 

 

U1

 

 

 

 

 

 

 

 

D4

2200UF 16V

 

 

7812

 

 

 

 

 

 

 

 

1

 

 

3

 

 

 

 

 

 

 

 

 

I

O

 

 

 

 

 

 

 

 

 

 

 

PM SERIES OUTS

 

 

 

 

 

 

C17

 

 

G

 

 

 

 

 

 

1N4001

R1

 

 

C7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1

 

4.7K

 

 

 

1U

 

 

 

 

IN 9-15 VAC/VDC

 

 

 

 

 

2

 

 

 

 

 

 

 

1N4001

 

 

 

 

 

 

 

 

 

 

J10

 

 

D5

 

 

 

 

 

 

 

 

 

D3

 

LDRR

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

1

1N4001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JAPDC

 

D2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1N4001

 

 

 

 

 

ROLLS CORPORATION

 

 

 

 

 

 

 

 

 

 

5968 S 350 West

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MURRAY UT

84107

 

 

 

 

 

 

 

 

 

 

PS16 PM POWER CENTER

 

 

 

 

 

 

 

 

 

 

 

Document Number:

 

 

Rev:

 

 

 

 

 

 

 

 

Ba

PS16.SCH

 

 

 

A

 

 

 

 

 

 

Date:

22 MAY 2002

Sheet

1

of

1

Page 2
Image 2
Rolls PS16 Personal Monitor, Power Center, Introduction, Features, Description, Connection / Operation, Specifications