Rosewill RV-380-2-FRB Overall Performance, Protection, Environment, Safety standards, Reliability

Models: RV-480-2-FRB RV-380-2-FRB RV-430-2-FRB

1 14
Download 14 pages 34.35 Kb
Page 7
Image 7
Overall Performance

POWER SUPPLY Value series

User Manual

 

 

 

Overall Performance

Efficiency

: 70% at typical full load and normal input voltage

Hold-Up Time

: 17ms at full load and normal input voltage

Switching Frequency : 60HZ at normal input.

Stability

: ±10%, for 24 hours after warm up.

Protection

Over Load Protection :

150% over load protection Over voltage protection :

Main output over 20% protection Short Circuit Protection :

All output equipped with short circuit protection

Environment

Operation Temperature : 0°c to +40°c

Storage Temperature : -40°c to +70°c

Operating Humidity : 10% to 90% RH

Storage Humidity : 10% to 90% RH

Safety standards

TUV/CE/CB/FCC/UL

EMI Standard

Meet with FCC class B and CISPR-22B

HI-POT Testing

Input to ground : 15KVac/10mA 3 second

Input to output : 15KVac/10mA 3 second

Insulation resistance

Input to ground : Min 50MProtection

Input to output : Min 50M

Reliability

MTBF : 50000 hours at 25°c ambient temperature