Rosewill RV380-2-FRB-S manual Meet with FCC class B and CISPR-22B

Models: RV380-2-FRB-S

1 14
Download 14 pages 47.16 Kb
Page 7
Image 7

POWER SUPPLY Value series

User Manual

 

 

 

Overall Performance

Efficiency :70% at typical full load and norminal input voltage Hold-Up Time : 17ms at full load and norminal input voltage Switching Frequency : 60HZ at norminal input.

Stability : ±10%, for 24 hours after warm up.

Protection

Over Load Protection :150% over load protection

Over voltage protection : Main output over 20% protection

Short Circuit Protection : All output equipped with short circuit protection

Environment

Operation Temperature : 0°c to +40°c

Storage Temperature : -40°c to +70°c

Operating Humidity : 10% to 90% RH

Storage Humidity : 10% to 90% RH

Safety standards

TUV/CE/CB/FCC/UL

EMI Standard

Meet with FCC class B and CISPR-22B

HI-POT Testing

Input to ground : 15KVac/10mA 3 second

Input to output : 15KVac/10mA 3 second

Insulation resistance

Input to ground : Min 50M

Input to output : Min 50M

Reliability

MTBF : 50000 hours at 25°c ambient temperature

6

© 2004-2006 Rosewill Inc. All rights reserved by Rosewill

Page 7
Image 7
Rosewill RV380-2-FRB-S manual Meet with FCC class B and CISPR-22B, Input to ground Min 50M Input to output Min 50M