Rotel RB-1091 Troubleshooting, Specifications, Front Panel Power Indicator Is, Not Lit, No Sound

Models: RB-1091

1 10
Download 10 pages 11.61 Kb
Page 8
Image 8
Troubleshooting

RB-1091Mono Power Amplifier

8

Troubleshooting

Specifications

 

 

 

Most difficulties in audio systems are the result of

 

 

 

 

poor or wrong connections, or improper control

Power Configurations

1 x 500 Watts

settings. If you encounter problems, isolate the

Watts/Channel

500 watts, with 20KHz filter, 8 ohm load,

area of the difficulty, check the control settings,

 

20-20 kHz, 0.03% THD

determine the cause of the fault and make the

Total Harmonic Distortion (20Hz-20kHz, 8 ohms)

 

 

 

necessary changes. If you are unable to get

Continuous Rated Power

< 0.03%

 

 

sound from the RB-1091, refer to the sugges-

One-Half Rated Power

< 0.03%

 

 

tions for the following conditions:

One Watt per Channel

< 0.03%

 

 

Front Panel Power Indicator Is

Power Output (4 Ohms, 0.09% THD)

1000 watts

 

 

Output Peak Current

40A

 

 

Not Lit

Intermodulation Distortion 60 Hz:7 kHz, 4:1

< 0.03%

 

 

No main power to the RB-1091. Check AC

Damping Factor (8 ohms)

400

 

 

power connections at the amplifier and the

Amp Gain

27.2dB

 

 

AC outlet. Check the front panel power switch.

Input Sensitivity/Impedance

2.2 V / 11.1 k ohms

Make sure that it is set to the ON position. If

Frequency Response

10 - 40 KHz (±3dB)

using 12V trigger power-on, make sure that

Signal to Noise Ratio (IHF A)

118 dB

 

 

a trigger signal is present at rear panel 12V

Power Requirements

 

 

 

TRIG IN jack.

USA

120 Volts, 60 Hz

No Sound

Europe

230 Volts, 50 Hz

Power Consumption

300 Watts

 

 

If the amp is getting AC power, but is producing

 

34 Watts - Idling

no sound, check the PROTECTION INDICATOR

 

3 Watts - Standby

on the front panel. If lit, see below. If not, check

Dimensions (W x H x D)

432 x 92 x 407 mm

all of your connections and control settings on

 

171/ x 35/ x 161/ in

associated components. Make sure that your

 

8

8

8

Panel Height (for rack mounting)

80 mm, 31/

in

input connections and speaker connections

 

 

8

 

Weight (net)

7.8 kg, 17.2 lb.

match your system configuration.

Protection Indicator Is Lit

The front panel PROTECTION INDICATOR will light when the RB-1091 protection circuits have shut off the amplifier. Typically, this oc- curs only when the amplifier has overheated, when there is faulty speaker wiring, or after a period of extreme use. Turn off the system and wait for the amp to cool. Then push the front panel power switch in and out to reset the protection devices. If the problem is not corrected or reoccurs, there is a problem with the system or the amplifier itself.

All specifications are accurate at the time of printing.

Rotel reserves the right to make improvements without notice.

Page 8
Image 8