Output Connections 6

English

Output Connections 6

[See Figure 2 for typical system connection illustration.]

Most power amplifiers have RCA-type input connectors that are compatible with the outputs of the RQ-970. Connect a set of cables between the outputs of the RQ-970 and one of the line level inputs of the amplifier. As always, use high quality cables and be sure to connect the Left and Right channel outputs of the RQ-970 to the correct channels of the amplifier.

Troubleshooting

Most difficulties in audio systems are the result of incorrect con- nections, or improper control settings. If you encounter problems, isolate the area of the difficulty, check the control settings, deter- mine the cause of the fault and make the necessary changes. If you are unable to get sound from the RQ-970, refer to the sugges- tions for the following conditions:

Power Indicator Is Not Lit

The Power Indicator should be lit whenever the RQ-970 is plugged into the wall power outlet and the power switch is turned on. If it does not light, test the power outlet with another electrical de- vice, such as a lamp. Be sure the power outlet being used is not controlled by a switch that has been turned off.

No Sound

Be sure the phonograph is functioning properly. Check the wiring from the back of the phono cartridge to the phonograph tone arm. Make sure the cables from the phonograph to the RQ-970 inputs are connected properly. Be sure the input selector on the control preamplifier (or integrated amplifier or receiver) is set to the proper input. Check all the other components in the signal path for power and proper operation. If the system has a separate pream- plifier and power amplifier, check the wiring between them. Also check the wiring between the speaker outputs and the speakers.

Specifications

Total Harmonic Distortion (20Hz-20kHz)

< 0.004%

Intermodulation Distortion (60 Hz : 7 kHz, 4:1)

< 0.004% at 1V output

Input Sensitivity / Impedance

210 V / 100 ohms

Phono - MC

Phono - MM

2.5 mV / 47 kOhms

Phono Overload (MC/MM)

16 mV / 160 mV

Output Sensitivity / Impedance

150 mV/ 100 Ohms

Frequency Response

20Hz-20kHz, ± 0.2dB

Signal to Noise Ratio (IHF “A” weighted)

70 dB

MC

MM

75 dB

Power Requirements

115 Volts, 60 Hz or

 

230 Volts, 50 Hz

Power Consumption

10 Watts

Dimensions (W x H x D)

440 x 72 x 195 mm

 

173/8 x 27/8 x 73/4

Weight (net)

3.1 kg, 6.8 lbs.

All specifications are accurate at the time of printing.