RuggedCom m2200 manual Type Test Specifications, Electrical Safety Levels Comments

Models: m2200

1 29
Download 29 pages 3.37 Kb
Page 26
Image 26

5.6 Type Test Specifications

 

Electrical Safety

 

Levels

 

Comments

 

Dielectric Withstand

 

2 kV RMS for 1 minute

 

ANSI/IEEE C37.90 (1989)

 

 

 

IEC 60255-5 (Section 6)

 

 

 

 

 

 

High Voltage Impulse

 

5 kV peak

IEC 60255-5 (Section 8)

 

Insulation Resistance

 

500 VDC for 1 minute

 

IEC 60255-5 (Section 6

Electrical Environment

Levels

Comments

High Frequency Disturbance

2.5 kV @ 1MHz for 2s

ANSI/IEEE C37.90.1

(Oscillatory)

IEC 60255-22-1

 

IEC Surge

4 kV / 2 kV

IEC 61000-4-5

(Level 4)

 

 

IEC Fast Transient

2 kV / 1 kV

IEC 61000-4-4

(Level 4)

 

 

ANSI/IEEE Fast Transient

4 kV

ANSI/IEEE C37.90.1

IEC Radiated RFI Immunity

10 V/m

IEC 61000-4-3

ANSI/IEEE Radiated RFI

20 V/m

ANSI/IEEE C37.90.2

Immunity

 

 

ESD

15 kV (air discharge)

IEC 61000-4-2

(Electrostatic Discharge)

8 kV (contact)

(Level 4)

Atmospheric Environment

Levels

Comments

Temperature (Dry Cold)

-40°C

IEC 60068-2-1

Test Ad: 16 hrs @ -40°C

 

 

Temperature (Dry Heat)

85°C

IEC 60068-2-2

Test Bd: 16 hrs @ 85°C

 

 

Humidity

95%

IEC 60068-2-30

non-condensing

Test Db: 6 cycles, 55°C, 95% Humidity

 

26

© 2008 RuggedCom Inc. All rights reserved

Rev105

Page 26
Image 26
RuggedCom m2200 manual Type Test Specifications, Electrical Safety Levels Comments, Electrical Environment Levels Comments