RuggedSwitch™ M2200
EMI and Environmental Type Tests
IEC
TEST | Description |
| Test Levels | Severity Levels | |
IEC | ESD |
| Enclosure Contact | +/- 8kV | 4 |
| Enclosure Air | +/- 15kV | 4 | ||
|
|
| |||
|
|
|
|
|
|
IEC | Radiated RFI |
| Enclosure ports | 20 V/m | x |
|
|
| Signal ports | +/- 4kV @ 2.5kHz | x |
|
|
|
|
|
|
|
|
| D.C. Power ports | +/- 4kV | 4 |
IEC | Burst (Fast Transient) |
|
|
|
|
| A.C. Power ports | +/- 4kV | 4 | ||
|
|
| |||
|
|
|
|
|
|
|
|
| Earth ground ports 3 | +/- 4kV | 4 |
|
|
| Signal ports | +/- 4kV | 4 |
IEC | Surge |
| D.C. Power ports | +/- 2kV | 3 |
|
|
|
|
|
|
|
|
| A.C. Power ports | +/- 4kV | 4 |
|
|
|
|
|
|
|
|
| Signal ports | 10V | 3 |
|
|
|
|
|
|
|
|
| D.C Power ports | 10V | 3 |
IEC | Induced (Conducted) RFI |
|
|
|
|
| A.C. Power ports | 10V | 3 | ||
|
|
| |||
|
|
|
|
|
|
|
|
| Earth ground ports 3 | 10V | 3 |
IEC | Magnetic Field |
| Enclosure ports | 40 A/m continuous, 1000 A/m for 1 s | N/A |
|
|
| D.C. Power ports | 30% for 0.1s, 60% for 0.1s, 100% for 0.05s | N/A |
IEC |
|
|
|
|
|
Voltage Dips & Interrupts |
|
| 30% for 1 period, 60% for 50 periods | N/A | |
|
|
| |||
|
|
| A.C. Power ports |
|
|
IEC |
|
| 100% for 5 periods, 100% for 50 periods 2 | N/A | |
|
|
| |||
|
|
| Signal ports | 2.5kV common, 1kV diff. mode@1MHz | 3 |
|
|
|
|
|
|
IEC | Damped Oscillatory |
| D.C. Power ports | 2.5kV common, 1kV diff. mode@1MHz | 3 |
|
|
| A.C. Power ports | 2.5kV common, 1kV diff. mode@1MHz | 3 |
|
|
|
|
|
|
IEC | Mains Frequency Voltage |
| Signal ports | 30V Continuous, 300V for 1s | 4 |
|
|
|
| ||
| D.C. Power ports | 30V Continuous, 300V for 1s | 4 | ||
|
|
| |||
|
|
|
|
|
|
IEC | Ripple on D.C. Power Supply |
| D.C. Power ports | 10% | 3 |
|
|
|
|
|
|
|
|
| Signal ports | 2kVac | N/A |
IEC | Dielectric Strength |
| D.C. Power ports | 2kVac | N/A |
|
|
|
|
|
|
|
|
| A.C. Power ports | 2kVac | N/A |
|
|
|
|
|
|
|
|
| Signal ports | 5kV | N/A |
|
|
|
|
|
|
IEC | H.V. Impulse |
| D.C. Power ports | 5kV | N/A |
|
|
|
|
|
|
|
|
| A.C. Power ports | 5kV | N/A |
IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS
Test | Description |
| Test Levels | Severity Levels | |
IEEE C37.90.3 | ESD |
| Enclosure Contact | +/- 8kV | N/A |
|
|
|
| ||
| Enclosure Air | +/- 15kV | N/A | ||
|
|
| |||
|
|
|
|
|
|
IEEE C37.90.2 | Radiated RFI |
| Enclosure ports | 35 V/m | N/A |
|
|
|
|
|
|
|
|
| Signal ports | +/- 4kV @ 2.5kHz | N/A |
|
|
|
|
|
|
IEEE C37.90.1 | Fast Transient |
| D.C. Power ports | +/- 4kV | N/A |
|
|
|
| ||
| A.C. Power ports | +/- 4kV | N/A | ||
|
|
| |||
|
|
|
|
|
|
|
|
| Earth ground ports3 | +/- 4kV | N/A |
|
|
|
|
|
|
|
|
| Signal ports | 2.5kV common mode @1MHz | N/A |
|
|
|
|
|
|
IEEE C37.90.1 | Oscillatory |
| D.C. Power ports | 2.5kV common, 1kV diff. mode@1MHz | N/A |
|
|
|
|
| |
|
| A.C. Power ports | 2.5kV common, 1kV diff. mode@1MHz | N/A | |
|
|
| |||
|
|
|
|
|
|
|
|
| Signal ports | 5kV | N/A |
|
|
|
|
|
|
IEEE C37.90 | H.V. Impulse |
| D.C. Power ports | 5kV | N/A |
|
|
|
|
|
|
|
|
| A.C. Power ports | 5kV | N/A |
|
|
|
|
|
|
|
|
| Signal ports | 2kVac | N/A |
IEEE C37.90 | Dielectric Strength |
|
|
|
|
| D.C. Power ports | 2kVac | N/A | ||
|
|
|
|
|
|
|
|
| A.C. Power ports | 2kVac | N/A |
|
|
|
|
|
|
MILITARY STANDARD TESTS
Description | Details | ||
Shock | Grade A, Equipment Class I, Shock Type A Equipment | ||
|
|
| |
Vibration | Type I (Upper Frequency of 33 Hz) | ||
|
|
| |
Electromagnetic Interference | CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE102, | ||
RS101, RS103 | |||
|
| ||
Magnetic Field - DC Magnetic Exposure | Section 070, Part 1 | ||
|
|
| |
Temperature - Low/High Temperature | Method 501 | ||
|
|
| |
Temperature - | Method 503 | ||
|
|
| |
Humidity | Method 507, Procedure IV |
Notes: 1. Only applicable to functional earth connections separated from the safety earth connection.
2.Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, ( e.g. shipboard application and for severe transportation conditions")
* Testing complete, pending final documentation (contact RuggedCom for complete details)
www.RuggedCom.com | RuggedSwitchTM M2200 | 5 |
|
|
|
|
|