RuggedCom Order Codes, RS416 Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6, Mount Mounting Options

Models: RS416

1 10
Download 10 pages 25.89 Kb
Page 9
Image 9
Order Codes

RuggedServerRS416

Modular 16-Port Serial Device Server with Integrated Managed Ethernet Switch

Order Codes

RS416 -______ -______ -____ -____ -____ -____ -____ -____ -____ -____

Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

RS416

Main: Ethernet and Power Connectors

S1, S2, S3, S4: Serial Port Modules for Slots 1, 2, 3, and 4

￿.R = Ethernet on rear; LED panel on front; power connector on rear

￿.XX = Empty (S2,S3,S4 Only)

￿.F = Ethernet on front; LED panel on front; power connector on rear

￿.3D

= 4 x RS232/RS422/RS485 via DB9

￿.B = Ethernet on rear; LED panel on top; power connector on rear

￿.3R

= 4 x RS232/RS422/RS485 via RJ45

￿.T = Ethernet on front; LED panel on top; power connector on rear

￿.FS = Fiber Serial Interface (ST Connector)

Mount: Mounting Options

￿.RM = 19" Rack Mount Kit

￿.DP = DIN and Panel Mount Kit

￿.RD = 19" Rack, DIN, and Panel Mount Kit

￿.00 = No Mounting Option

PS1 and PS2: Power Supply 1 and 2

￿.24 = 24VDC (9-36VDC), screw terminal block ￿.48 = 48VDC (36-59VDC), screw terminal block ￿.HI = 88-300VDC or 85-264VAC, screw terminal block ￿.24P = 24VDC (9-36VDC), pluggable terminal block ￿.48P = 48VDC (36-59VDC), pluggable terminal block

￿.HIP = 88-300VDC or 85-264VAC, pluggable terminal block ￿.XX = No Power Supply (PS2 Only)

Example Order Codes:

RS416-R-RM-24-XX-3D-3D-XX-XX-TX01-XXXX

19" Rack mounted, 24VDC power supply, 2 10/100 RJ45 Ethernet Ports, 8 DB9 Serial Ports, with all Ports on the rear

RS416-F-RM-48-48-3R-3R-3R-3R-FX01-FX01

19" Rack mounted, Dual 48VDC power supply, 4 100FX (Multi Mode 1300nm Fiber) Ethernet ports, 16 RJ45 Serial Ports, with all Ports on the front

RS416-F-RM-HI-XX-3R-3R-3D-3D-FX01-TX01

19" Rack mounted, HI power supply, 2 100FX (Multi Mode 1300nm Fiber) Ethernet Ports, 2 10/100 RJ45 Ethernet Ports, 8 RJ45 Serial Ports, 8 DB9 Serial Ports, with all Ports on the front

S5, S6: Ethernet Modules for Slots 5 and 6

￿.XXXX = Empty (S6 Only)

￿.TX01 = 2 x 10/100Tx RJ45

￿.FL01 = 2 x 10FL - Multimode, 850nm, ST ￿.FX01 = 2 x 100FX - Multimode, 1300nm, ST ￿.FX02 = 2 x 100FX - Multimode, 1300nm, SC ￿.FX11 = 2 x 100FX – Multimode, 1300nm, LC ￿.FX03 = 2 x 100FX - Multimode, 1300nm, MTRJ

￿.FX04 = 2 x 100FX - Singlemode, 1300nm, ST, 20km ￿.FX05 = 2 x 100FX - Singlemode, 1300nm, SC, 20km ￿.FX06 = 2 x 100FX - Singlemode, 1300nm, LC, 20km ￿.FX07 = 2 x 100FX - Singlemode, 1300nm, SC, 50km ￿.FX08 = 2 x 100FX - Singlemode, 1300nm, LC, 50km ￿.FX09 = 2 x 100FX - Singlemode, 1300nm, SC, 90km ￿.FX10 = 2 x 100FX - Singlemode, 1300nm, LC, 90km

Accessories/Options

82-01-0002 - Conformal Coating

41-11-0011 - Cable support brackets

43-10-0007 - Power cable (North America three prong connector -> beau)

www.RuggedCom.com