RS900 Family Installation Guide
6.4.3 Fiber Optic Ethernet Port Specifications
Order
Code Speed
Standard Mode /
Connector Tx
(nm)
Cable
Type
(um)
Tx
min
(dBm)
Tx
max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Typical
Distance
(km)
Power
Budget
(dB)
MJ 100FX MM/MTRJ 1300 50/125 -22.5 -14 -33.5 -14 2 11
62.5/125 -19 -14 -33.5 -14 2 14.5
MC 100FX MM/SC 1300 50/125 -22.5 -14 -33.9 -14 2 11.4
62.5/125 -19 -14 -33.9 -14 2 14.9
MT 100FX MM/ST 1300 50/125 -22.5 -14 -33.9 -14 2 11.4
62.5/125 -19 -14 -33.9 -14 2 14.9
ML 100FX MM/LC 1310 62.5/125 -19 -14 -32 -14 2 13
T2 100FX SM/ST 1310 9/125 -15 -7 -34 -3 20 19
L2 100FX SM/LC 1300 9/125 -15 -8 -38 -3 20 23
C2 100FX SM/SC 1300 9/125 -15 -8 -31 -7 20 16
L5 100FX SM/LC 1310 9/125 -5 0 -35 -3 50 30
C5 100FX SM/SC 1310 9/125 -5 0 -34 -3 50 29
L9 100FX SM/LC 1310 9/125 0 5 -37 0 90 37
C9 100FX SM/SC 1310 9/125 5 0 -37 0 90 42
Table 17 - Fiber Optic Port Specifications
NOTES:
1. All values listed are average values
2. To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.
3. Maximum segment length is greatly dependent on factors such as fiber quality, and number of patches and
splices. Please consult RuggedCom sales associates when determining maximum segment distances.
Page 35 of 42
© 2008 RuggedCom Inc. All rights reserved. Rev100