RuggedWirelessTM RS900W

Wireless Ethernet with Integrated 8-Port Managed Switch

EMI and Environmental Type Tests

NEMA TS-2 Requirements

 

Test

 

 

 

 

 

Description

 

 

 

Levels

 

 

 

Performance Criteria*

 

TS-2 1998, Section 2, para 2.2.7.3

 

Temperature: Low Temperature/Low

 

89.0 VAC @ -34°C

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS-2 1998, Section 2, para 2.2.7.4

 

Temperature: Low Temperature/High

 

135.0VAC @ -34°C

EUT Continued to function properly during

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and following all temperature and humidity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature: High Temperature/High

 

 

 

 

 

 

TS-2 1998, Section 2, para 2.2.7.5

 

 

135.0VAC @ + 75°C

 

 

testing

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS-2 1998, Section 2, para 2.2.7.6

 

Temperature: High Temperature/Low

 

89.0VAC @ + 75°C

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS-2 1998, Section 2 para. 2.2.8.4

 

Vibration Endurance Test

 

0.5g @ 30Hz for 1hr on all three planes

EUT functioned properly following test pro-

 

 

 

cedure. No physical damage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS-2 1998, Section 2, para 2.1.10

 

 

Mechanical Shock

 

+/-10g half sine wave for 11msec on all

EUT functioned properly following test pro-

 

 

 

 

 

three planes

 

cedure. No physical damage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Transients: High Repetition Noise

One +/-300VDC pulse every other cycle

EUT functioned properly during and follow-

 

TS-2 1992, Section 2, para. 2.1.6.1

 

once every 3 seconds across 360 ° of line

 

 

 

 

 

 

(AC Terminals)

 

 

cycle (2500W peak)

ing test procedure. No damage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS-2 1998, Section 2 para. 2.1.6.2

 

Electrical Transients: Low-Repetition High

One +/-600VDC pulse every second, ran-

EUT functioned properly during and follow-

 

 

Energy (AC Terminals

 

domly distributed across 360 ° of line

ing test procedure. No damage

 

 

 

 

 

 

 

cycle. Ten pulses total.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS-2 1998, Section 2, para 2.1.7

 

Electrical Transients: I/O Terminals

 

One +/-300VDC pulse every second, mini-

EUT functioned properly during and follow-

 

 

 

 

mum 5 pulses per port

ing test procedure. No damage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TS-2 1992, Section 2, para. 2.1.8

 

Electrical Transients: Nondestruct

 

One +/-1000VDC pulse every two seconds,

EUT functioned properly following test pro-

 

 

Transient Immunity (AC Terminals)

 

 

3 per each polarity.

 

cedure. No damage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-6-2 EMC Generic Standard: Immunity for Industrial Environments

 

 

 

 

Test

 

 

 

Description

 

 

Levels

 

RuggedCom Test Level

Performance Criteria*

 

IEC 61000-4-2

 

 

ESD

 

Enclosure Contact

 

 

+/- 4kV

 

+/- 8kV

B

 

 

 

 

Enclosure Air

 

 

+/- 8kV

 

+/- 15kV

B

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-3

 

Radiated RFI

 

Enclosure ports

 

10 V/m, 80 to 1000Mhz

 

20V/m

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

 

+/- 1kV @ 5kHz

 

+/- 4kV @ 2.5kHz

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-4

Burst (Fast Transient)

 

D.C Power ports

 

 

+/- 2kV @ 5kHz

 

+/- 4kV

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.C. Power ports

 

 

+/- 2kV @ 5kHz

 

+/- 4kV

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

 

+/- 1kV line-to-earth

 

+/- 2kV line-to-earth, +/- 2kV

B

 

 

 

 

 

 

 

 

 

 

line-to-line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-5

 

 

Surge

 

D.C Power ports

 

+/- 0.5kV line-to-earth/line

+/- 4kV line-to-earth, +/- 2kV

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

line-to-line

 

 

 

 

 

 

 

 

A.C. Power ports

 

+/- 2kV line-to-earth, +/- 1kV

+/- 4kV line-to-earth, +/- 2kV

B

 

 

 

 

 

 

 

 

 

line-to-line

 

line-to-line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

 

10V @ 0, 5-80 MHz

 

10V @ 0, 5-80 MHz

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D.C Power ports

 

 

10V @ 0, 5-80 MHz

 

10V @ 0, 5-80 MHz

A

 

IEC 61000-4-6

Induced (Conducted) RFI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.C. Power ports

 

 

10V @ 0, 5-80 MHz

 

10V @ 0, 5-80 MHz

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Earth ground ports

 

 

10V @ 0, 5-80 MHz

 

10V @ 0, 5-80 MHz

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 61000-4-8

 

Magnetic Field

 

Enclosure ports

 

 

30 A/m @ 50, 60 Hz

 

40 A/m continuous, 1000

A

 

 

 

 

 

 

A/m for 1s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30% reduction for 0.5

 

30% for 1 period

B

 

 

 

 

 

 

 

 

 

 

 

period

 

 

IEC 61000-4-11

 

Voltage Dips

 

A.C. Power ports

 

 

 

 

 

 

 

 

 

 

 

>95% reduction for 250

 

100% for 5 periods, 100%

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

periods

 

for 50 periods

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

 

2kVac

 

2kVac

N/A

 

 

 

 

 

 

 

 

(Fail-Safe Relay output)

 

(Fail-Safe Relay output)

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 60255-5

Dielectric Strength

 

D.C. Power ports

 

 

2kVac

 

2kVac

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.C. Power ports

 

 

2kVac

 

2kVac

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal ports

 

 

5kV

 

5kV

N/A

 

 

 

 

 

 

 

 

(Fail-Safe Relay output)

 

(Fail-Safe Relay output)

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 60255-5

 

H.V. Impulse

 

D.C. Power ports

 

 

5kV

 

5kV

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.C. Power ports

 

 

5kV

 

5kV

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Environmental Type Tests

 

 

 

 

 

 

Test

 

 

 

 

 

Description

 

 

 

 

 

Test Levels

 

 

Severity Levels

 

IEC 60068-2-1

 

 

 

Cold Temperature

 

Test Ad

 

 

-40°C, 16 Hours

 

 

N/A

 

IEC 60068-2-2

 

 

 

Dry Heat

 

Test Bd

 

 

+85°C, 16 Hours

 

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 60068-2-30

 

Humidity (Damp Heat, Cyclic)

 

Test Db

 

95% (non-condensing),

 

N/A

 

 

 

 

 

55°C , 6 cycles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 60255-21-1

 

 

 

Vibration

 

Tests Fc

 

2g @ (10 - 150) Hz

 

Class 2 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IEC 60255-21-2

 

 

 

Shock

 

 

 

Tests Ea

 

 

30g @ 11mS

 

 

Class 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes: 1. Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, ( e.g. shipboard application and for severe transportation conditions")

www.RuggedCom.com

RuggedWireless™ RS900W

6

 

 

 

 

 

Page 6
Image 6
RuggedCom RS900W warranty EMI and Environmental Type Tests, Test Description Levels

RS900W specifications

The RuggedCom RS900W is a powerful and versatile wireless router designed specifically for critical infrastructure applications. It combines the essential features of a rugged networking device with advanced wireless communication capabilities, making it an optimal choice for industries such as utilities, transportation, and industrial automation.

One of the standout features of the RS900W is its robust construction. Built to withstand harsh environmental conditions, this router has an IP67 rating, meaning it is dust-tight and can withstand immersion in water. This level of protection ensures the device operates reliably in extreme temperatures, humidity, and exposure to corrosive elements, which are common in outdoor and industrial environments.

The RS900W employs advanced wireless technology, supporting both 802.11ac and 802.11n standards. This dual-band capability enables users to leverage both 2.4 GHz and 5 GHz frequency bands, providing flexible connectivity options. The router supports a multitude of Wireless Distribution System (WDS) applications, enabling easy and efficient expansion of wireless networks without the need for additional cabling.

In terms of security, the RS900W incorporates state-of-the-art features to protect critical data. It supports WPA3, allowing for enhanced encryption and stronger authentication mechanisms. The router also offers Virtual LAN (VLAN) support, which helps to segregate network traffic for improved security and performance management. Access Control Lists (ACLs) further enhance the security by allowing administrators to define who can access the network based on specific criteria.

Network management is simplified with the RS900W’s intuitive web-based interface, which provides real-time monitoring and control options. The device supports SNMP (Simple Network Management Protocol), making it easy for network administrators to oversee the health and status of the network remotely. The ability to integrate with existing SCADA (Supervisory Control and Data Acquisition) systems makes the RS900W even more suitable for critical infrastructure applications.

With its rugged build, advanced wireless capabilities, and strong security features, the RuggedCom RS900W is well-equipped to meet the demands of connecting and managing devices in challenging industrial settings. It ensures reliable communication in environments where traditional networking solutions may fail. As industries increasingly rely on connected devices, the RS900W stands out as a dependable choice for maintaining robust and secure wireless networks.