RuggedCom RSG2200 manual Description Usage, PS1 Live / +, Source is AC, Testing, PS1 Neutral

Models: RSG2200

1 33
Download 33 pages 52.03 Kb
Page 16
Image 16

Terminal #

 

 

Description

 

Usage

 

 

 

 

 

 

 

 

 

 

 

PS1 Live / + is connected to the positive (+) terminal if the

1

 

 

PS1 Live / +

 

power source is DC or to the (Live) terminal if the power

 

 

 

 

 

source is AC.

 

 

 

 

 

PS1 Surge Ground is connected to the Chassis Ground via

 

 

 

 

 

a jumper on the terminal block. Surge Ground is used as the

2

 

 

PS1 Surge Ground

 

ground conductor for all surge and transient suppression

 

 

 

circuitry. NOTE: Surge Ground must be disconnected

 

 

 

 

 

 

 

 

 

 

from Chassis Ground during HIPOT (dielectric strength)

 

 

 

 

 

testing.

 

 

 

 

 

PS1 Neutral / - is connected to the negative (-) terminal if

3

 

 

PS1 Neutral / -

 

the power source is DC or to the (Neutral) terminal if the

 

 

 

 

 

power source is AC.

 

 

 

 

 

Chassis Ground is connected to the Safety Ground

4

 

 

Chassis Ground

 

terminal for AC inputs or the equipment ground bus for DC

 

 

 

inputs. Chassis ground connects to both power supply surge

 

 

 

 

 

 

 

 

 

 

grounds via a removable jumper.

 

 

 

 

 

PS2 Live / + is connected to the positive (+) terminal if the

5

 

 

PS2 Live / +

 

power source is DC or to the (Live) terminal if the power

 

 

 

 

 

source is AC.

 

 

 

 

 

PS2 Surge Ground is connected to the Chassis Ground via

 

 

 

 

 

a jumper on the terminal block. Surge Ground is used as the

6

 

 

PS2 Surge Ground

 

ground conductor for all surge and transient suppression

 

 

 

circuitry. NOTE: Surge Ground must be disconnected

 

 

 

 

 

 

 

 

 

 

from Chassis Ground during HIPOT (dielectric strength)

 

 

 

 

 

testing.

 

 

 

 

 

PS2 Neutral / - is connected to the negative (-) terminal if

7

 

 

PS2 Neutral / -

 

the power source is DC or to the (Neutral) terminal if the

 

 

 

 

 

power source is AC.

8

 

 

Relay NO Contact

Normally open, failsafe relay contact.

9

 

 

Relay Common

Failsafe relay common contact.

10

 

 

Relay NC Contact

 

Normally closed, failsafe relay contact.

Table 3: RSG2200 Power terminal block connection description

 

16

2008 RuggedCom Inc. All rights reserved

Rev105

Page 16
Image 16
RuggedCom RSG2200 Description Usage, PS1 Live / +, Source is AC, Testing, PS1 Neutral, Power source is AC, Chassis Ground