English
34
ELECTRICAL CONNECTIONBefore connecting the machine to the power point, make sure that
the rating corresponds with the one indicated on the rating-plate of
the power cord.
STANDARD Connection Star connection with earthed centre point.
Delta connectionTo change the connection from a star connection to a
delta connection, modify the connections shown in
the diagram (beside) on the power cord, the input
terminal board (A), and the branching terminal bo-
ard (B).
Single-Phase connectionTo change the connection from a star connection to a
single-phase connection, modify the connections
shown in the diagram (beside) on the power cord,
the input terminal board (A), and the branching termi-
nal board (B).
Single-Phase Connection withThree-Core Power CordTo change the connection from a three-phase con-
nection to a single-phase star connection, change
the power cord and replace it with a three-core power
cord of the HO7RN-F 3x4 mm
2
type (SJO 3x10 AWG
for machines used in the USA).
Add the supplied two jumpers (C) to the input termi-
nal board (A) and modify the connections on the input
terminal board (A) and on the branching terminal
board (B) as shown in the diagram (beside).
Normally, the machines are preset for a star connection with ear-
thed centre point.
V415 - 400 3N~
V240 - 230 3~
V240 - 230 ~
V240 - 230 ~
COD. 4001165000