The Servo Quad Amplifier Protection Circuitry

As noted in the “Guided Tour” section of this manual, the Servo Amplifier's front panel Protection lights indicate the activity of the relay speaker connection circuitry. When the Protection lights are lit, this circuitry is inactive, and all connected speakers are muted (provided with 0 volts DC), thus protecting them and preventing any audible “thump” from occurring.

The following conditions will cause the Protection lights to go on:

Initial power-up:For approximately five seconds after initial power-up, the relay speaker connection circuitry is deactivated and the speaker output is muted. If everything is operating normally, you will hear an audible click at the conclusion of this brief period, as the circuitry is activated and the Servo Quad Amplifier begins delivering signal to connected speakers. It is normal for the Protection light to fade gradually after the amplifier is powered off.

WARNING: If a Protection light fails to go out (and you fail to hear the accompanying audible click) approximately five seconds after power-up, turn the Servo Quad Amplifier off immediately and check all external devices and wiring for possible shorts or other defects.

CH3/4

PROTECTION

Overheating: A temperature sensing device in the Servo Quad Amplifier will cause the relay speaker connection circuitry to be deactivated (and the Protection light to go on) whenever the operating temperature of the unit rises above a safe level. To guard against this problem, make sure the Servo Quad Amplifier receives adequate ventilation on all sides (see page 5 for more information); in extreme environmental conditions, you may also want to consider the use of cooling fans.

Severe overcurrent conditions: This occurs whenever the signal being input to the Servo Quad Amplifier rises to a level above 20% THD (Total Harmonic Distortion).

Shorted speaker cables: This will occur if, due to faulty wiring, the hot and ground signals being output by the Servo Quad Amplifier short one another.

Output impedance drops below 2 ohms: This can occur if the Servo Quad Amplifier is connected to inappropriate speaker systems (see the “Setting Up and Using the Servo Quad Amplifier” section on page 5 in this manual for more information).

DC voltage detected at speaker output: The most likely cause of this is an internal failure.

In general, any time either or both of the Protection lights go on (other than during the approximately five seconds following initial power-up), there is reason to be concerned. If this occurs, turn the Servo Quad Amplifier off immediately and carefully check all wiring and external devices in order to locate and correct the condition that caused the light to go on in the first place.

8

Page 8
Image 8
Samson 4060/4120 owner manual Servo Quad Amplifier Protection Circuitry

4060/4120 specifications

The Samson 4060/4120 series represents a robust line of industrial signalling devices designed to provide reliable alarm and indication systems across a myriad of applications. Engineered with precision and utility in mind, these products serve a pivotal role in safety and operational efficiency in industries ranging from manufacturing to hospitality.

One of the standout features of the Samson 4060/4120 series is its flexible configuration options. Users can easily tailor these devices to meet specific operational needs by adjusting settings such as alarm thresholds, tones, and volumes. This adaptability is further enhanced by compatibility with various power supplies, including AC and DC voltages, making them suitable for diverse environments.

In terms of technologies, the Samson 4060/4120 incorporates advanced digital signal processing (DSP), which ensures crystal-clear audio output. The DSP technology minimizes distortion and enhances sound quality, allowing the devices to produce loud, attention-grabbing signals that can be heard over ambient noise. Additionally, the series includes a wide array of alarm tones and patterns, providing clear differentiation for various alerts.

Durability is another hallmark of the Samson 4060/4120 devices. Constructed with high-quality materials, they are designed to withstand harsh conditions, including extreme temperatures, dust, and moisture. This ruggedness ensures that the devices remain operational in challenging environments, which is crucial for industries that cannot afford downtime.

The series also features easy installation and maintenance. With user-friendly interfaces and accessible wiring options, operators can quickly install and maintain the devices with minimal training. This simplicity reduces labor costs and enhances the overall efficiency of alarm system management.

Moreover, the Samson 4060/4120 series meets international safety standards, ensuring compliance with regulations across various sectors. This compliance provides peace of mind for businesses, knowing that they are utilizing equipment that adheres to strict safety protocols.

In summary, the Samson 4060/4120 series combines flexibility, advanced technology, and robust construction to deliver a reliable signalling solution. These devices not only enhance safety but also streamline operational processes, making them essential for industries that prioritize performance and reliability in their alarm and indication systems.