Drain hose installation

1.If necessary, connect the 2-meter extension drain hose to the drain hose.

2.If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.

3.Fit the drain hose into 1 of 2 drain hose holes, then fix the end of the drain hose tightly with a clamp.

• If you do not use the other drain hose hole, block it with a rubber stopper.

4. When extending the Drain Hose, hold the end of Drain Hose and Extended Hose,

 

rotate and insert the drain hose into Extended hose for 15~20 mm. Make sure the

Drain hose hole

two hoses are firmly connected, there is no water leakage.

 

5.Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose.Then, Use vinyl tape to wrap the each side of connection by 20mm .

15~20 mm

20mm

20mm

or more

or more

ENGLISH

Drain hose

Extension

Drain hose

Extension

 

drain hose

 

 

 

drain hose

6.Pass the drain hose under the refrigerant pipe, keeping the drain hose tight.

7.Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture.

8.Using natural drainage method, check the drainage is normal.

Vinyl Tape Foam Insulation

Shield

Drain hose

Extension drain hose

• The hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page

37~38 for further details.

Make sure the installed direction of the drain hose is correct.

Inadequate installation may cause condensate water leakage.

• If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.

DO NOT WALL UP THE DRAIN HOSE CONNECTION !

Drain hose connection must be easy accessible and serviceable.

Changing direction of the drain hose

Change the direction only when it is necessary.

1.

Detach the rubber cap with the plier.

 

Screw hole

 

 

 

2.

Detach the drain hose by pulling it and turning to the left.

Screw

3.

Insert the drain hose by fixing it with the screw into the groove of the drain

 

 

hose and the outlet of the drain pan.

 

Drain hose

4.

Attach the rubber cap with a screwdriver by turning it to the right until it

 

 

fixes to the end of the groove.

 

 

5.

Check for leakage on both side of the drain outlet.

Drain pan outlet

 

Pour the water in direction of arrow.

Direction of the drained water

 

Rubber cap

• Make sure the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part.

33